Technical Data

M
M
M
O
O
O
R
R
R
T
T
T
A
A
A
R
R
R
M
M
M
I
I
I
X
X
X
P
P
P
R
R
R
O
O
O
D
D
D
U
U
U
C
C
C
T
T
T
N
N
N
O
O
O
.
.
.
1
1
1
1
1
1
0
0
0
2
2
2
PRODUCT USE
QUIKRETE
®
Mortar Mix is a construction grade mortar mix designed
for laying brick, concrete masonry units and stone. QUIKRETE
®
Mortar Mix is a pre-blended, sanded product. The standard
formulation meets ASTM C 270 and C 1714 for Type N mortar.
COLORS
QUIKRETE
®
Mortar Mix is available in gray and additional colors by
special order. Color can also be added to the product as it is mixed by
adding QUIKRETE
®
Stucco and Mortar Color (#1319) to the mixing
water. Twenty standard colors are available.
SIZES
• QUIKRETE
®
Mortar Mix -
• 60 lb (27.2 kg) bags
• 80 lb (36.3 kg) bags
YIELD
• Each 80 lb (36.3 kg) bag of QUIKRETE
®
Mortar Mix will lay up to 37
standard bricks or 13 standard (8” x 8” x 16” [200 x 200 x 400 mm])
blocks.
TECHNICAL DATA
APPLICABLE STANDARDS
ASTM International
• ASTM C 270 Specification for Mortar for Unit Masonry
• ASTM C 387 Specification for Packaged, Dry, Combined Materials
for Mortar and Concrete
• ASTM C 1714 Specification for Preblended Dry Mortar Mix for Unit
Masonry
PHYSICAL/CHEMICAL PROPERTIES
QUIKRETE
®
Mortar Mix meets or exceeds the property requirements
of ASTM C 270, ASTM C 387 and ASTM C 1714 for the type
selected. Refer to Appendix XI of ASTM C270 for guidance in
selecting the proper mortar type. See Table 1.
INSTALLATION
SURFACE PREPARATION
Surfaces to receive Mortar Mix should be clean and free of dirt, loose
debris, grease, oil, etc., for the best possible bond.
MIXING
• For each 80 lb (36.3 kg) bag, add 9 pt (4.3 L) of fresh water to mixer
• Turn the mixer on and begin adding bags of Mortar Mix
• If the material becomes too difficult to mix, add additional water until
a workable mix of trowelable consistency is obtained
Note - Final water content should be 9 - 14 pt (4.3 - 6.6 L) for each 80
lb (36.3 kg) bag and 7 - 10 pt (3.3 - 4.7 L) for each 60 lb (27.2 kg)
bag.
INSTALLATION
• Apply a full bed of mortar onto the base, approximately 1/2" - 3/4"
(12.7 - 19.1 mm) thick
• Push downward into the mortar bed and sideways against the
previously laid block with a slight twisting motion
• Tool the mortar joints when they become thumbprint hard. This will
make the mortar joint watertight and provide a neat appearance
Table 1
Hydraulic Cement- Lime Mortars or Cement Mortars
Type Minimum Compressive Water Retention Air content
Strength, psi (MPa) Minimum % Maximum %
M 2500 (17.2) 75 12
S 1800 (12.4) 75 12
N 750 (5.2) 75 14
1
O 350 (2.4) 75 14
1
Masonry Cement Mortars
Type Minimum Compressive Water Retention Air content
Strength, psi (MPa) Minimum % Maximum %
M 2500 (17.2) 75 18
S 1800 (12.4) 75 18
N 750 (5.2) 75 20
2
O 350 (2.4) 75 20
2
1
When structural reinforcement is included, the maximum air content shall be 12%
2
When structural reinforcement is included, the maximum air content shall be 18%
CURING
Curing of masonry mortars is required only if conditions are very hot,
dry or windy. In such cases, a gentle mist of water applied to the
surface will prevent premature drying and improve the strength of the
mortar.
PRODUCT DESCRIPTION
QUIKRETE
®
Mortar Mix is a construction grade mortar mix designed for laying brick,
concrete masonr
y
units and stone.
Masonry Mortaring
04 05 13
DIVISION 4

Summary of content (2 pages)