Specification

Note - Products meeting ASTM C887 are accepted by BOCA, SBCCI
and IBC for use in dry stack construction and for damp-proofing of
basement walls.
PHYSICAL/CHEMICAL PROPERTIES
QUIKWALL
®
SBC meets the requirements of ASTM C887 as shown
in Table 1. The QUIKWALL
®
SBC system of block construction
provides walls of superior strength as shown in Table 2. QUIKWALL
®
SBC not only provides improved flexural and racking strength, but
greater impact resistance. Recommended design requirements for
non-reinforced surface bonded walls of hollow concrete masonry units
are based on gross area of CMU.
Allowable stress - QUIKWALL
®
SBC meets ANSI A41.1 except as
follows:
• Compressive, 45 psi (0.3 MPa)
• Shear, 10 psi (0.07 MPa)
• Flexural horizontal span, 30 psi (0.2 MPa)
• Flexural vertical span, 18 psi (0.1 MPa)
Requirements for lateral supports, minimum wall thickness, and
height-to-thickness ratios are the same for QUIKWALL
®
SBC as for
mortared construction.
ENVIRONMENTAL CONSIDERATIONS
QUIKWALL
®
SBC walls are almost impermeable to air and water,
although they are not a vapor barrier. QUIKWALL
®
SBC is
noncombustible and adds to the fire rating of concrete masonry units.
QUIKWALL
®
SBC resists air penetration, sound transmission and
water penetration, while at the same time providing structural strength
improvement.
QUIKWALL
®
SBC adds thermal resistance or R-value of
approximately 0.4 ft2 × h × °F/Btu (0.07 m2 × K/W) to the cross
section of a wall. Table 3 contains environmental property test data
showing comparisons between uncoated and coated block surfaces
TABLE 1 PHYSICAL PROPERTIES OF QUIKWALL
Flexural strength, ASTM C887
1 day 450 psi (3.1 MPa)
7 days 700 psi (4.8 MPa)
28 days 800 psi (5.5 MPa)
Compressive strength, ASTM C887
1 day 1600 psi (11 MPa)
28 days 3500 psi (24.1 MPa)
INSTALLATION
GENERAL
QUIKWALL SBC is designed to be used in the construction of new
concrete block walls where the walls are laid up dry stacked (in a
running bond pattern) without mortar above the first course in
accordance with ASTM C946. Grout, reinforcing, anchorage and
control joints are the same as for conventional mortared walls as
designated by The American Concrete Institute (ACI) and National
Concrete Masonry Association (NCMA). QUIKWALL
®
SBC must be
applied to both sides of dry-stacked concrete block at a minimum of
1/8" (3.2 mm) thickness. Porous walls must be pre-wet prior to
application of QUIKWALL
®
SBC to avoid water being withdrawn from
the mixture. Premature drying on the wall will prevent proper
hydration, thereby causing the surface to be chalky and perhaps
exhibit map or craze cracking. After application of QUIKWALL
®
SBC
and after final set is achieved, dampen QUIKWALL
®
SBC walls to
ensure proper curing and hydration. QUIKWALL
®
SBC can be applied
by trowel or spray. A one-coat application is all that is required as
long as the surface texture is accomplished before the QUIKWALL
®
Surface Bonding Cement attains initial set. Walls constructed by this
technique are structurally twice the flexural strength of concrete block
walls built with conventional mortar.
REHABILITATING & RENOVATING WALLS
The performance characteristics of QUIKWALL
®
SBC make it
adaptable for rehabilitating and renovating existing wall surfaces. Old
walls coated with QUIKWALL
®
SBC on one side will exhibit
structurally improved environmental properties and a new aesthetic
look. The use of QUIKRETE
®
Acrylic Fortifier with QUIKWALL
®
SBC
is required when application is made to other than uncoated block
wall surfaces. The installation of galvanized expanded metal lath may
also be required for walls that have been previously painted or
coated, or structural walls to which a cementitious modified system is
not adaptable due to variations in thermal expansion.
SURFACE FINISHES
QUIKWALL
®
SBC surfaces can be given attractive textured finishes
by using suitable spray equipment or with plasterer’s hand tools.
Surface textures from a smooth surface finish to very deep relief
stucco can be achieved. It is also possible to provide accent panels to
simulate exposed aggregate concrete or to provide a simulated brick
wall appearance.
MIXING
Machine mixing is recommended. Mix 1 gal (3.8 L) of clean water with
each 50 lb (22.7 kg) bag of QUIKWALL
®
SBC. Place the water in the
mixer and add the QUIKWALL
®
SBC to the water. Adjust water as
necessary to achieve desired consistency. Do not use more than 1
1/2 gal (5.7 L) of water per bag. Mix no more than 3 minutes to avoid
filamentizing the glass fibers.
CURING
QUIKWALL
®
SBC walls must be fog cured after having achieved final
set. This is essential to ensure proper hydration of the thin surface
application.