Lighting and Extinguishing the Burner System
1. Place a lighted long-stem match near the right end
of the top burner (do not hold the match in your
hand) or use a lighted long-necked butane lighter
(Fig. 10-1).
2. Slowly turn the fi replace remote valve to the ON
position. The log set should light.
3. If the log set does not light before the match
goes out, immediately turn the valve to the OFF
position.
4. Wait approximately fi ve (5) minutes to clear out any
gas, and repeat steps 1-3 above.
5. If the log set fails to light again, turn off the valve
and contact the dealer or gas supplier.
6. To extinguish the Real-Fyre
®
gas log set, simply turn
the valve to the OFF position. Be sure the valve is
turned fully off to avoid any gas leakage.
Cleaning and Checking
A periodic check of the following should be performed
at least annually by a qualifi ed professional service
representative.
1. Flue system for proper venting.
2. Damper operation
3. Orifi ces for dirt or other foreign matter.
4. Visual check on the burner.
5. Air mixers for dust/lint blockage.
6. Excessive soot on logs.
Lighting and Operating Instructions
BEFORE LIGHTING, smell all around the burner area for gas. IF YOU SMELL GAS, FOLLOW THE INSTRUCTIONS ON
THE COVER (P. 1).
WARNING: If you do not follow these instructions exactly, a fi re or explosion may result causing
property damage, personal injury or loss of life.
Do not use this appliance if any part has been underwater. Immediately call for a qualifi ed professional
service technician to inspect the appliance and to replace any part of the burner system which has been
under water.
FOR YOUR SAFETY, READ BEFORE LIGHTING