User's Manual

25
Quick Guide
Operation
Setup will automatically begin.
Step 6
Note
Automatic Easy Setup process will take approximately 20 seconds.
Constant Maximum DL Output Power 43dBm
if DL Input Power >= -52dBm.
Maximum Gain 85dB if DL Input Power < -52dBm.
After running Automatic Easy Setup or ,VRODWLRQ0HDVXUHPHQW, ,VRODWLRQ
value is displayed with “GOOD” when the isolation is higher than 110dB, or it is
displayed with the actual value when the isolation is lower than 110dB.
Automatic Level Control: Type under 43 and then click APPLY and ON.
[Example]
For the repeater with 43dBm maximum output power, 95dB maximum
JDLQG%JDLQFRQWUROUDQJHĺ,ILQSXWVLJQDOG%PDQG$/&LVVHWDV
43dBm, the gain will be 88dB to adjust to the output power.
If input signal is -60dBm, the output power will be 35dBm by the limitation
of the maximum gain even though the ALC is set as 43dBm.