- RAD Data Communications Network Card User's Manual
ARC-101
Installation & Operation Manual Chapter 4. Software Management
Performance Monitoring Window 4-7
•
Link Status
•
ATM Status
PERFORMANCE MONITORING
1. Link Status
2. ATM Status
3. Reset Counters
ESC. Exit
Link Status
The Link Status window displays:
•
The number of alarms and errors detected in the last second ("Last
Second" column).
•
The number of errors detected since the last counter reset or overflow
("All" column).
•
The time (in seconds) since the last counter reset.
Link Status
STS-3C (FIBER) Last Second ALL T3 (Coax) Last Second ALL
LOS 0 0 LOS 0 0
LOF 0 0 OOF 0 0
LOP
LOC 0 0 AIS 0 0
SLM 0 0 Yellow 0 0
Line AIS 0 0 BIP 0 0
Path AIS 0 0 FEBE 0 0
Line FERF/RDI 0 0 P1/P2 0 0
Path FERF/RDI 0 0
Section BIP 0 0 PLCP LOF 0 0
Line BIP 0 0 PLCP YELLOW 0 0
Path BIP 0 0
Line FEBE 0 0 PLCP BIP 0 0
Path FEBE 0 0 PLCP FEBE 0 0
Example: Link Status window for ARC-101 in SONET-T3 configuration