- RAD Data Communications TDMoIP Gateways Installation and Operation Manual IPmux-1, IPmux-1E

Chapter 5 Application Configuration Procedures IPmux-1/1E Installation and Operation Manual
5-10 IPmux-4
4. Select Next Hop and enter the next hop router IP address (this parameter is
only necessary if the Destination IP Address is not in the same subnet as this
IPmux. In such cases the Ethernet frame will be sent to the next hop IP
address).
5. Select Destination Bundle and enter 33 (which is the destination bundle on
IPmux-4).
6. Press <Esc> to return to the Bundle Connection Configuration screen.
7. Press <Esc> to return to the Main screen.
Remember to press <Enter> after modifying each parameter. Press <S> to save
all changes on the menu.
5.3 IPmux-4
Powering-up
To turn on IPmux-4:
1. Make sure all IPmux-4 cables and connectors are properly connected.
2. Connect IPmux-4 to a PC equipped with an ASCII terminal-emulation
application (for example, Windows 95 Hyper Terminal or Procomm).
3. Turn on the control-terminal PC and set its default port parameters to
19,200 baud, 8 bits/character, No Parity, 1 stop bit.
4. Set the terminal emulator to ANSI VT100 emulation (for optimal view of
system menus).
5. Switch ON the POWER supply switch, located on the rear panel.
6. When the initialization and self-test are over, a menu appears displaying
initialization and self-test results. If the self-test is successful, the RDY LED on
the left side of the front panel lights up.
To logon:
1. Press <Esc> to open the configuration software.
2. Enter your User Name as Supervisor (su) and press <Enter>.
3. Enter your Password (the factory-set password is xxxxxxxxxx).
If you enter an invalid password in three consecutive attempts the system becomes
inaccessible for 15 minutes.
Note
Note