User's Manual

Table Of Contents
Chapter 4 Configuration FCD-IPM Installation and Operation Manual
4-14 Security Setup Menu
Device Access Restriction
Parameters listed on this screen allow you to control access to FCD-IPM
configuration from the control port or from LAN/WAN (via Telnet and SNMP).
Enabling Telnet Access
FCD-IPM supports Telnet. This allows FCD-IPM to be configured and controlled
over the WAN and LAN using TCP/IP.
Access to Telnet requires authentication by the device, using username and
password.
By default, Telnet access to FCD-IPM is disabled to prevent changes being made to
the unit's configuration parameters.
To enable Telnet access:
1. From the Security Setup menu, select option 1, Device Access Restrictions.
2. From the Device Access Restrictions menu, select option 1, TELNET Access
Status and change it to Enable.
3. Select options 2 and 3 to change the User name and Password, if required.
FCD-IPM can now be accessed using your TELNET username and password.
Enabling SNMP Access
By default, access to FCD-IPM via SNMP is disabled. Blocking SNMP access
prevents changes being made to the unit's configuration parameters.
To enable SNMP access:
1. From the Security Setup menu, select option 1, Devise Access Restrictions.
2. From the Devise Access Restrictions menu, select option 4, SNMP Access
Status and change it to Enable.
3. Select options 5, 6, and 7 to change Read, Write and Trap communities, if
required.
FCD-IPM can now be accessed for SNMP operation using the appropriate
communities.
Changing Login Password
Entrance to configuration screens, via terminal from the control port, is set by the
factory default as Protected by Password. The default password is 1234.
To change the password or remove password protection:
1. From the Security Setup menu, select option 1, Device Access Restrictions.
2. From the Device Access Restrictions menu, select option 8, Monitor User
Password.
3. Enter a new value for the Password.