Specifications

Chapter 4 Configuration Installation and Operation Manual
4-8 Configuring Optimux-106 for Operation Optimux-106 Ver. 6.1
Parameter Possible Value
(default value in
bold)
Description
Alarms Masked
Unmasked
Identifies whether alarms triggered by this
Ethernet port are masked or not. When
masked, these alarms are not trapped and
are not recorded in the log file.
3. Select Port Number to set the Fast Ethernet port number to MNG-ETH or
USER-ETH.
4. Select Port Name to set a name to the port (USER-ETH only).
5. Select Autonegotiation and toggle between the Enabled and Disabled
options.
6. Select Flow Control to toggle between the Enabled and Disabled options.
7. Select Alarms to mask or unmask the Fast Ethernet alarms.
Configuring the Ethernet User Port
³ To configure the Ethernet User port:
1. From the Ethernet menu (
Figure
4-10
), select Port Number.
The Port Number menu opens.
Configuration>Physical Layer>Ethernet>Port Number
1. ETH-MNG
2. ETH-USER
>
Please select item <1 to 2>
ESC-prev. menu; !-main menu; &-Exit 1 User(s)
Figure
4-11. Port Number Menu
2. From the Port Number Menu (see
Figure
4-11
) choose ETH-USER.
The Ethernet User menu appears.
Optimux-106
Main Menu>Configuration>Physical Layer>Ethernet
1. Device number > (Local)
2. Port number > (USER-ETH)
3. Administrative status (UP)
4. Port name …()
5. Auto Negotiation (Enabled)
6. Flow Control > (Enabled)
7. Alarms > (Unmasked)
Please select item <1 to 7>
ESC-Previous menu; !-Main Menu; &-Exit 1 User(s)
Figure
4-12. Ethernet USER Menu