Specifications

Installation and Operation Manual Chapter 4 Configuration
Optimux-106 Ver. 6.1 Configuring Optimux-106 for Operation 4-9
Table
4-9
describes the fields in the Ethernet management menu.
Table
4-7. Ethernet USER Parameters
Parameter Possible Value Description
Device Number Local
Remote
Identifies the device Location
Port number MNG-ETH
USER-ETH
Opens menu for the MNG-ETH port
Opens menu for the USER-ETH port
Port name String up to 15
characters
A name easily Identifies the Ethernet port
Administrative
Status
UP
Down
Port status is up.
Port status is down.
Autonegotiation Enabled
Disabled
Enables autonegotiation.
Flow Control Enabled
Disabled
Enables flow control.
Alarms Masked
Unmasked
Identifies whether alarms triggered by this
Ethernet port are masked or not. When
masked, these alarms are not trapped and
are not recorded in the log file.
3. Select Administrative Status and set the status to either Up or Down.
4. Select Port Name to set a name to the port (ETH-USER only).
5. Select Autonegotiation and toggle between the Enabled or Disabled options.
6. Select Flow Control to toggle between the Enabled or Disabled options.
7. Select Alarms to mask or unmask the USER Ethernet alarms.
Configuring Fault Propagation
Optimux-106 has an option of Alarm Forwarding (Fault propagation) of the
USER-ETH port. The user can enable or disable this option.
The control port is used to connect a console terminal to Optimux-106.
Configuration>System
1. Management >
2. Control Port >
3. Fault Propagation (Off)
4. Alarms >
5. Redundancy >
6. Factory Default >
Please select item <1 to 3>
ESC-Previous menu; !-Main Menu; &-Exit 1 User(s)
Figure
4-13. Control Port Menu