Specifications

Chapter 5 Monitoring and Diagnostics Installation and Operation Manual
5-2 Monitoring Performance Optimux-106 Ver. 6.1
Parameter Description
Event Log Displays the number of events logged by the system.
To view the events, enter 2.
Status Enter 3 to display the detailed system status.
Interface Status Displays the current interface status.
To view the detailed interface status, enter 4.
Clear Log File To clear the log file, enter 5
Monitoring the Status of the System
The System Status screen displays the current status of the local or remote
Optimux-106 unit.
Optimux-106
Monitoring>System>Status
1. Device Number > (Local)
Device Type > (Optimux-106)
Force Link > (LINK A)
Active Link > (LINK A)
Redundancy mode > (AUTO)
Redundancy Status > (Available)
PS A status > (OK)
PS B status > (OK)
Alarm Indication > (Major)
Test Indication > (Off)
>
Please select item <1 to 1>
ESC-Previous menu; !-Main Menu; &-Exit 1 User(s)
Figure
5-2. System Status Screen
Table
5-2. System Status Parameters
Parameter Description
Device Number
Indicates the Optimux-106 currently being monitored:
Local
Remote
Device type Displays the device type
Redundancy status Indicates if redundancy is available or not available
Available – two uplinks are mounted
Not Available – only one uplink is mounted or Redundancy
mode is ‘OFF’