Specifications

Installation and Operation Manual Chapter 5 Monitoring and Diagnostics
Optimux-106 Ver. 6.1 Handling Alarms 5-9
Table
5-7. Alarm Configuration Parameters
Parameter Possible Values Description
Device Number Local
Remote
Sets whether local or remote
device is to be masked or
unmasked
Alarms Masked
Unmasked
Masked – The selected device
alarms are masked
Unmasked – The selected
device alarms are unmasked
Remote Connection
Failed
Masked
Unmasked
Masked – The selected remote
connection alarm are masked
Unmasked – The selected
remote connection alarm are
unmasked
List of Alarms and Events
The Optimux-106 alarms are described in
Table
5-8
.
Table
5-8. Optimux-106 System Alarms
Code Message on terminal Description Severity
1 PS A fail No voltage in power supply A. Major
2 PS B fail No voltage in power supply B. Major
3 Remote connection FAIL A managment connection could not be established with
the remote device.
Major
4 Redundancy not
available
Redundancy mode is set to AUTO or MANUAL but the
second link is not installed.
Major
30 ETH Integrity fail Failure in Ethernet management port
integrity or in the fast Ethernet integrity.
ETH-MNG
ETH
Major
31 Signal Loss Signal loss detected on uplinks or
channels.
T1
Link
Major
33 Rx AIS Received AIS on the uplinks or the
channels.
T1 Minor
The Optimux-106 events are described in
Table
5-9
.
Table
5-9. Optimux-106 Events
Code Event Description
100 Software process failed Failed to process software download.
101 Buffer overflow The event log buffer exceeded its maximum size and new events are
written over the old ones.