Specifications

Chapter 5 Monitoring and Diagnostics Installation and Operation Manual
5-14 Performing Diagnostic Tests Optimux-106 Ver. 6.1
This test checks the operation of the connections to the equipment attached to
the local tributary interfaces.
Local Optimux-106
Tr i b u t ar y
Interface
Mux/Demux
Uplink Interface
AIS
~
Tr i b u t ar y
Interface
Tr i b u t ar y
Interface
Tr i b u t ar y
Interface
Figure
5-12 T1 Local Loopback in Optimux-106
Each port can be set separately.
Uplink Local Loopback in the Optimux-106
The Uplink local loopback returns the transmit signal of the active Uplink interface
to the input of the receive path. Simultaneously, the local Optimux-106 sends an
unframed all-ones signal to the uplink.
Figure
5-13
shows the Uplink local loopback connection.
When this loopback is activated, the equipment connected to the local
Optimux-106 tributary must receive its own transmission.
This test checks the operation of the local Optimux-106, and the connections to
the equipment attached to the tributary interfaces.