System information

Chapter 3 Configuration Management IPmux-8/16 User’s Manual
3-8 Configuring General Parameters
Table 3-4. System Parameters (Cont.)
Parameter Possible Values / Remarks
Redundancy Disabled (Off): forces the device to start using Main (Link 1) imediately, no
matter what is its state and stay there
Enabled: system will use the following values (based on Recovery)
When Recorvery=Yes: Auto: device switches back to main link when valid
When Recorvery=No: Manual: device doesn't switch back to main link
Default Interface Forces the device to use specific link
LAN1 (Main): device starts to use of Main (Link 1) immediately, no matter what
is its state and stays there. No Redundancy.
LAN2 (Backup): device starts to use of Backup (Link 2) immediately, no matter
what is its state and stays there. No Redundancy.
Recovery Yes, No
Wait to Restore (sec) Time device has to wait in the redundant state until it goes back to the default
link
30, 60
ETH1 Card Aging Time
(sec)
ETH1 Card Aging Time in seconds
Unchecked
Checked: 16..4080
Note: parameter enabled only if there is a card in Slot 1
ETH2 Card Aging Time
(sec)
ETH2 Card Aging Time in seconds
Unchecked
Checked: 16..4080
Note: parameter enabled only if there is a card in Slot 2
Configuring System Information
To set system information for the selected IPmux device:
1. Configuration > System Info...
The System Information dialog box appears (Figure 3-5).
2. Enter the required settings. You can change the Name, Contact, Location,
Date and Time fields.
3. Click <Set> to implement the changes.