System information

IPmux-8/16 User’s Manual Chapter 3 Configuration Management
Configuring IPmux-8/16 Ports at the Physical Layer 3-23
Table 3-10. E1/T1 Parameters (Cont.)
Parameter Possible Values / Remarks
Conditioning CAS (ABCD)
(for E1)
Conditioning CAS (AB)
(for T1)
Trunk conditioning signaling value after alarm detection
0x1 to 0xF: E1
0x0 to 0xF: T1 ESF
0x0 to 0x3:T1 D4
Alarms that can cause trunk conditioning: LOS, LOF, AIS at the far end E1/T1
port or receive buffer underrun/overrun at the local ATM level
For E1 ports, this parameter is applicable only when the Line Type is E1-MF or
E1-CRC-MF.
For T1 ports, this parameter is not applicable when the Signaling Mode is None.
First 2.5 Sec. Signaling
Conditioning
(only applicable for T1
ports, except when the
Signaling Mode is None or
when Line Type is
unframed)
Trunk conditioning signaling; the value to be sent as a signaling during the first
2.5 seconds after alarm detection
0x0 to 0xF, FF: T1 ESF
0x0 to 0x3, FF: T1D4
Alarms that can cause trunk conditioning: LOS, LOF, AIS at the far end E1/T1
port or receive buffer underrun/overrun at the local ATM level.
Conditioning Data Pattern Trunk conditioning data pattern to be sent upon a DS0 fail
0x0 to 0xFF
Alarms that can cause trunk conditioning: LOS, LOF, AIS at the far end E1/T1
port or receive buffer underrun/overrun at the local ATM level.
Not applicable when the Line Type is Unframed.
In unframed mode, Condtioning will be a result of LOS (Loss of Signal) at the far
end E1/T1 port or receive buffer underrun/overrun at the local ATM level and
will cause AIS tramsission towards the PBX.
AIS Transmit Enables/disables AIS transmit when Ethernet cable (for TDMoIP) is out
(disconnected)
Enabled, Disabled