Anybendinthechimneyorconnectingfluepipeshouldnotexceed45°.
90°bendsshouldnotbeused.
Combustiblematerialshouldnotbelocatedwheretheheatdissipatingthroughthe
wallsoffireplacesorfluescouldigniteit.Thereforewheninstallingthestoveinthe
presenceofcombustiblematerialsdueaccountmustbetakenoftheguidanceonthe
separationofcombustiblematerialgiveninBuildingRegulationsApprovedDocument
Jandalsointhesestoveinstructions.
Ifitisfoundthatthereisexcessivedraughtinthechimneythenadraughtstabiliser
shouldbefitted.Fittingofadraughtstabiliserwillaffecttherequirementforthe
permanentairsupplyintotheroominwhichthestoveisfittedinaccordancewith
ApprovedDocumentJ(seealsocombustionairsupply).
Adequateprovisione.g.easilyaccessiblesootdoorordoorsmustbeprovidedfor
sweepingthechimneyandconnectingfluepipewhereitisnotintendedforthe
chimneytobesweptthroughtheappliance.
ChimneyFires
Ifthechimneyisthoroughlyandregularlyswept,chimneyfiresshouldnotoccur.
However,ifachimneyfiredoesoccurturnoffthestoveimmediatelyandisolatethe
mainselectricitysupply(ifapplicable),andtightlyclosethedoorsofthestove.This
shouldcausethechimneyfiretogoout.Ifthechimneyfiredoesnotgooutwhenthe
aboveactionistakenthenthefirebrigadeshouldbecalledimmediately.Donotrelight
thestoveuntilthechimneyandfluewayshavebeencleanedandexaminedbya
professional.