Datasheet

3.1 Power Derating Curve: Operating Temperature Range
- 55 ~+170
For resistors operated in ambient temperatures above 70
, power rating shall be
derated in accordance with figure below.
Rating Power (%)
Ambient Temperature( )
100
80
60
40
20
0
0 25 50 75 100 125
150-55
170
70
3.2 Rating Current:
Rated Current: The resistor shall have a DC continuous working current or a
RMS(Root Mean Square). AC continuous working current at commercial-line
frequency and wave form corresponding to the power rating, as determined from the
following:
I= Rating current (A)
P= Rating power (w)
R= Nominal resistance (Ω)
I = P/R
3
/
13
Page No.
2011
/
10
/
19
Released Date
IE-SP-022
Document No.
Metal Alloy Low-Resistance
Resistor Specifications
RALEC
Do not copy without permission
Issue Dep. DATA Center.
Series No.
60
IT’ S NOT UNDER CONTROL FOR PDF FILE
PLS NOTE THE VERSION STATED.
Remark