Instructions / Assembly

CAUTION
After the conrmation of the above conditions, prepare the wiring as follows:
Never fail to delegate an individual power circuit specically for the air conditioner. For the
method of wiring, use the circuit diagram posted on the inside of the control cover as a guide.
The screws which fastens the wiring in the casing of electrical ttings are liable to come loose
Specication of power source.
Conrm that the electrical capacity is sucient.
Conrm that the cable thickness is as specied in the power source specication.
Always install an earth leakage circuit breaker in a wet or moist area.
from vibrations to which the unit will be subjected during the course of transportation. Check to
make sure they are all tightly fastened. (If they are loose, the wires could burn out.)
The following could be caused by a voltage drop: The vibration of a magnetic switch (which will
damage the contact point), the breakage of a fuse, or the disturbance of the normal function of
the overload.
See that the starting voltage is maintained at more than 90 percent of the rated voltage
marked on the name plate.
Before terminals are accessed, all supply circuits must be disconnected.
The means for disconnection from a power supply must be incorporated in the xed wiring
and have an air gap contact separation of at least 0.12 in (3 mm) in each active (phase) conductor.
Page 19
Wiring
Model E
Model F
Model G