User guide

32
10. Technical Data
THIS COOKER IS CATEGORY: CatII
2H3+.
It is supplied set for group H natural gas. A conversion kit from NG to LP is available for the cooker.
INSTALLER: Please leave these instructions with the user.
DATA BADGE LOCATION: Cooker back, serial number repeater badge below oven door opening.
COUNTRY OF DESTINATION: GB, IE.
Connections
Gas (Rp ½ at rear right-hand side) Electric
Natural Gas 20 mbar
230 / 400 V 50 Hz Butane 29 mbar
Propane 37 mbar
Dimensions Refer to ‘Positioning the Cooker’.
Overall height minimum 900 mm maximum 925 mm
Overall width 1100 mm
Overall depth 600 mm to fascia; 648 mm over handles
Minimum space above hotplate 650 mm
Ratings
Hotplate Bypass Screw*
Natural Gas 20mb L.P. Gas
Injector Injector
Wok burner 57 3.5 kW
internal 78
3.5 kW (246 g/h)
internal 53
external 126 external 82
Large burner 40 3.0 kW 134 3.0 kW (210 g/h) 87
Medium burner 32 1.7 kW 109 1.7 kW (119 g/h) 68
Small burner 28 1.0 kW 75 1.0 kW (70 g/h) 51
Ceramic Hob Front element Rear element
Power rating 1.1 kW 1.1 kW
* The valves in this cooker are fitted with adjustable bypass screws. The cooker is supplied with the bypass screws set for
Natural gas. For LPG conversion the bypass screws must be screwed all the way down.
Oven Efficiencies
Ovens
Left-hand Oven Right-hand Oven
Multi-function Forced Air Convection
Maximum power output @ 230 V 50 Hz 3.7 kW 2.5 kW
Energy eciency class on a scale of A (more ecient) to G (less ecient) A A
Energy consumption based on standard load 0.95kWh 0.90kWh
Usable volume (litres) 69 69
Size Large Large
Time to cook standard load 41 minutes 41 minutes
Surface area of the grid 1400cm
2
1400cm
2
Grill 2.3 kW
Maximum total electrical load at 230 V (approximate total including oven lights, oven fan, etc.): 10.8 kW.