Owner manual

AIR FILTRATION
REQUIRMENTS
It is the user's responsibility to insure clean, dry air at
all times. Turbine failure resulting from contaminated
air will not be covered under warranty. The following
pre-lter and bearing air lter(s) (see Figure 5) are
recommended for use in Aerobell Copes systems. See
Figure 5 if other lters are incorporated in the system
- the lters to be used must have ltering capacities
equal to or greater than those shown in Figure 5.
PSI RPM (unloaded) SCFM
60,000 (max.)
56,000
52,600
48,300
43,400
37,700
31,000
23,000
13,000
18.0
15.8
14.2
13.0
11.4
9.7
7.9
6.1
3.9
Figure 4: Turbine Air Pressure / RPM / SCFM
Aerobell Copes - Introduction
> Air must be properly ltered to assure ex-
tended turbine life and to prevent contamina-
tion of the paint job. Air which is not adequately
ltered will foul the turbine air bearings and cause
turbine failure. The correct type of lters must
be used in an Aerobell Copes system. The lter
elements must be replaced on a regular schedule
to assure clean air.
C A U T I O N
!
8
Ransburg
Filter Model No.
HAF-503
RPM-417
RPM-418
HAF-15 Element, One
RPM-32 Elements,
Carton of 4
RPM-33 Elements,
Carton of 8
Pre-lter, removes coarse amounts of oil, moisture &
dirt. Used upstream of RPM-417 pre-lter (used in
systems with poor air quality).
Pre-lter, coalescing type, 136 scfm, 98.5% eciency
particulate removal .3 to .6 micron, max. aerosol passed
1.0 micron, max. solid passed .4 micron (dependent upon
scfm requirement per applicator).
Bearing airlter, coalescing type, 19 scfm, 99.995%
eciency particulate removal .3 to .6 micron, max. aerosol
passed .6 micron, max. solid passed .2 micron (one per
applicator).
Description / Specications
Replacement
Element Part No.
Figure 5a: Aerobell Copes Models Recommended Air Filtration
LN-9230-00.1
45
40
35
30
25
20
15
10
5