Owner manual

Aerobell Copes - Operation
ELECTRODE REMOVAL
PROCEDURE FOR OPTIONAL
DIRECT CHARGING METHOD
-REFER TO FIGURE 8
1. Verify that high voltage is OFF. The
high voltage must be turned OFF before
performing any maintenance.
2. Remove item 7 (13521-03, compression nut)
and high voltage cable from port marked
HV.
3. Remove item 22i (13521-03, compression nut)
and ground cable from port marked GND.
4. Remove item 14 (14061-02, conductive foam
insert), item 13 (76562-00, spring loaded
contact pin screw assembly), item 12 (75841-
00, high voltage cable support tube) and item
9 (LSOR0007-06, O-Ring) from port marked
HV.
5. Remove item 5 (Qty-6, 75847-00, electrode
body retaining nuts) and item 6 (Qty-6, 76719-
00, electrode body assemblies).
6. Remove item 3 (Qty-20, M5 x 40mm long,
slotted llister head screws) and item 4 (Qty-
5, 75854-02, 90° connector electrode body
assembly.) Items 3 and 4 (marked “B”) must
be removed prior to removing items 3 and
15 (marked A”).
7. Remove item 3 (Qty-4, M5 x 40mm long,
slotted llister head screws) and item 15
(75854-01, 90° connector electrode body
assembly.) Unit damage may occur if items
3 and 15 (marked A”) are removed prior to
disassembly of items 9, 12, 13 and 14 (marked
“C”) and items 3 and 4 (marked “B”).
8. Install item 9 (LSOR0007-06, O-Ring), item 12
(75841-00, high voltage cable support tube)
and item 7 (13521-03, compression nut) into
port marked HV.
9. Install 73033-20F, 1/4-28 x 5/8 long nylon
socket head cap screw (not shown), into item
12 (75841-00, high voltage cable support
tube). Torque screw to 3-5 inch pounds.
10. Install 1/4 dia. x 3" long nylon rod (non-
conductive) material (not shown) into item 12
(75841-00, high voltage cable support tube)
and tighten item 7 (13521-03, compression
nut).
11. Install S10364-00, (Qty-6, 90° connector port
cap, not shown), LSOR0007-05, (Qty-6, o-ring,
not shown) and item 3 (Qty-24, M5 x 40mm,
long slotted llister head screws) in ports
marked A and B. Torque screws to 3-5 inch
pounds. Unit damage may occur if screws
are over torqued.
12. Install high voltage cable into port marked
GND and tighten item 22i (13521-03,
compression nut).
16
COATING MATERIAL
CONDUCTIVITY
The Aerobell Copes can be used with a full range of
conductive coatings including solvent-borne and
waterborne materials. Charging methods include:
Indirect charge for use with waterborne, grounded
uid systems. The uid system, including the
applicator, are connected to ground potential and
voltage is applied to the external electrodes. (See
Figure 8.)
Direct charge for use with solventborne, grounded
uid systems with electrodes removed. The uid
system is connected to ground potential and
voltage is applied to the applicator. (See Figure
8.)
Direct charge for use with waterborne, isolated uid
systems with electrodes removed. The uid system
is isolated from ground potential and voltage is
applied to the applicator. (See Figure 8.)
LN-9230-00.1