Owner manual

Aerobell Copes - Maintenance
20
Figure 9: Replacement Elements
Part#
HAF-15
RPM-32
RPM-33
1
4
8
HAF-503, Pre-Filter
RPM-417, Pre-Filter
RPM-418, Bearing Air
Filter
Qty. Elements
Per Carton
Used On
Verify that high voltage is OFF, turbine drive air is
OFF, and that the bell cup has stopped spinning. The
bearing air and shaping air should remain ON.
Clean all external surfaces of the applicator using a
lint-free rag dampened with solvent. External surfaces
include the quick-change applicator, retaining nut,
rear manifold, and electrodes.
After cleaning, all conductive residue must be
removed using a non-conductive solvent. Since
electrostatic equipment is involved, these solvents
should also be non-polar.
Weekly Maintenance
Follow all procedures as described under daily
maintenance prior to performing any weekly
maintenance.
Verify that shaping air is OFF, remove the shaping
air ring and cap from the applicator for thorough
cleaning.
Clean the shroud edge, which mates with the
shaping air ring taper, using a lint-free rag dampened
with solvent.
Clean the shaping air ring taper, which mates with
the shroud edge, using a soft bristle brush dipped in
solvent.
Clean all external surfaces of the air ring and cap
using a lint-free rag dampened with solvent.
Remove the cap for cleaning inside surfaces. The
parts may be soaked in clean solvent only, to loosen
paint that has wicked around the cap.
After removing the cap, use a soft bristle brush
dipped in solvent to clean the grooves, male threads
of the air ring, and female threads of the cap.
Paint residue found in the shaping air or exhaust
holes is not acceptable and must be removed prior
to assembly.
After cleaning, all conductive residue must be
removed using a non-conductive solvent. Since
electrostatic equipment is involved, these solvents
should also be non-polar.
MEAN TIME BETWEEN FAILURE
Air Filters / Element Replacement
Ransburg Aerobell Copes systems include a pre-
lter(s) and a nal lter for all air to the Aerobell
Copes unit. The nal lter is for bearing air only.
All lters contain elements that must be replaced
on a regular basis to assure clean air. RPM-417 and
RPM-418 lters also contain an automatic drain and
pressure dierential indicator.
LN-9230-00.1
> The high voltage must be turned OFF
before entering the spray area and performing
any maintenance procedures. Spray booth ex-
haust fan(s) should remain ON while cleaning
the equipment with solvents.
W A R N I N G
!
> Introducing air which contains oil, mois-
ture and dirt may cause wear and damage to
the bearings. It is the users responsibility to
monitor the quality of air and to replace the
lter elements as often as necessary. Turbine
failure caused by poor air quality will not be
covered under warranty.
C A U T I O N
!