Owner manual

Aerobell Copes - Safety
AREA
Tells where hazards
may occur.
HAZARD
Tells what the hazard is.
SAFEGUARDS
Tells how to avoid the hazard.
Spray Area
Improper operation or
maintenance may create a hazard.
Personnel must be properly
trained in the use of this
equipment.
Personnel must be given training in accordance
with the requirements of NFPA-33, Chapter 16, 1995
edition.
Instructions and safety precautions must be read and
understood prior to using this equipment.
Comply with appropriate local, state, and national
codes governing ventilation, re protection,
operation maintenance, and housekeeping. OSHA
references are Sections 1910.94 and 1910.107. Also
refer to NFPA-33, 1995 edition and your insurance
company requirements.
General Use and
Maintenance
Fire Hazard
Improper or inadequate
operationing and maintenance
procedures will cause a re hazard.
Protection against inadvertent
arcing that is capable of causing
re or explosion is lost if any safety
interlocks are disabled during
operation. Frequent power supply
shutdown indicates a problem in
the system requiring correction.
Fire extinguishing equipment must be present in the
spray area and tested periodically.
Spray areas must be kept clean to prevent the
accumulation of combustible residues.
Smoking must never be allowed in the spray area.
The high voltage supplied to the atomizer must be
turned o prior to cleaning, ushing or maintenance.
When using solvents for cleaning:
Those used for equipment ushing should have ash
points equal to or higher than those of the coating
material.
Those used for general cleaning must have ash
points above 100
°
F (37.8
°
C).
Spray booth ventilation must be kept at the rates
required by NFPA 33, 1995 Edition, OSHA and local
codes. In addition, ventilation must be maintained
during cleaning operations using ammable or
combustible solvents.
Electrostatic arcing must be prevented.
Test only in areas free of combustible material.
Testing may require high voltage to be on, but only as
instructed.
Non-factory replacement parts or unauthorized
equipment modications may cause re or injury.
If used, the key switch by-pass is intended for use
only during set-up operations. Production should
never be done with safety interlocks disabled.
Never use equipment intended for use in waterborne
installations to spray solvent based materials.