Operation Manual

Pag.18
6. POSITIONING, ASSEMBLY AND INSTALLATION
6.1 Environment of use
The positioning of the stove is decisive for successful even heating of the
room. Before deciding where to place the stove, the following must be taken
into account:
the stove must be installed on a floor with a sufficient carrying capacity. If
the existing building does not meet this requisite, appropriate measures
must be taken (i.e. load distribution plate).
the combustion air cannot be obtained from a garage or from an area with-
out ventilation or exchange of air, but from a free or external space
the stove must not be installed in a bedroom, bathroom or shower, or where
there is already another heating appliance without an autonomous air flow
(chimney, stove etc.)
in the case of a wood floor, prepare the floor-protection pedestal (glass plate or
steel)
installation is better in a large and central room in the house to ensure
maximum circulation of the heat;
connection to the mains supply is recommended using an earth socket (if
the cable supplied is not long enough to reach the nearest socket, use an
extension flush with the ground);
the stove must be placed in a position that receives the necessary level of air
for appropriate combustion of the pellets (at least 40 m
3
/h must be available),
in accordance with installation regulation and local legislations;
the minimum volume of the installation area must be 30 m
3
.
The installer of the stove should guarantee an installation with easy access
to the stove and of the chimney
The stove must be installed and assembled by qualified personnel.
The room must be:
prepared for the environmental functioning conditions
prepared with an adequate system of evacuation of smoke
have a 230V 50 Hz (EN73-23) electricity mains supply
have external ventilation (minimum section 100 cm
2
)
have a CE compliant earthing system
The stove must be connected to a SINGLE flue or – internal or exter-
nal - vertical pipe in compliance with the regulations in force.
The smoke is the result of the combustion of wood therefore if it
comes into contact with the walls it may dirty them.
It is not compulsory to connect the air intake of the stove directly
with the outside but at least 50m3/h of air must be guaranteed.
The use of a mesh at the end of the exhaust pipe is absolutely forbid-
den as this could cause the poor functioning of the stove.
Tubes and joints with adequate silicone gaskets must always be used
to guarantee the seal of the smoke pipes.
For the connection to the flue, no more than 3 90° bends must be
used and they must not be used more than 2-3 metres in horizontal.
IMPORTANT!!!! If the installation of the product is supposed to be
next to flammable wall, the minimum distance, indicated on the la-
bel located on the back of the stove, must be respect. In case the
product is installed next to unflammable walls no specific distances
are required.
The installation can not be done in a shared flue.
6.2. Examples of installation
This type of installation (see Fig. 9) requires an insulated flue, as all the
smoke pipe has been installed outside the house.
Height
Width
Depth
Weight
Diameter of smoke exit tube
Max. volume of heating
Thermal power
Hourly consumption of pellets
Electrical power absorbed during
operation
Supply
Tank capacity
Autonomy
Effi ciency
CO at 13%O
2
Smoke mass
Minimum draught
Smoke temperature
mm mm mm Kg mm m
3
Kw/h
min
-
max
Kg/h
min
-
max
W
V
-
Hz
Kg
h
min
-
max
%
min
-
max
%
min
-
max
g/s
min
-
max
mbar
-
Pa
°C
min
-
max
AURORA
CANAL.
1177 520 520 155 80 300
2.5
-
12.5
0.7
-
2.6
110
230
-
50
22
8.5
-
31.5
89
-
85
0.013
-
0.028
4.81
-
8.60
0.1
-
10
121
-
281
AURORA
VENTIL.
1191 520 520 150 80 300
2.5
-
12.5
0.75
-
2.8
280
230
-
50
15
5.3
-
20
90
-
86.5
0.014
-
0.028
4.57
-
8.40
0.1
-
10
114
-
265
CAMILLA
1189 525 510 141 80 240
2.8
-
10
0.6
-
2.2
110
230
-
50
23
9.5
-
38
87.5
-
91
0.012
-
0.029
3.8
-
7.4
0.1
-
10
83
-
189
EVA
VISION
1068 500 545 134 80 240
2.8
-
10
0.6
-
2.2
110
230
-
50
15
6
-
25
87.5
-
91
0.012
-
0.029
3.8
-
7.4
0.1
-
10
83
-
189
FLAVIA
1003 513 488 92 80 220
2.8
-
9
0.5
-
1.8
110
230
-
50
13
8.3
-
30
>
87.5
0.020
-
0.040
0.29
-
0.81
0.1
-
10
153
-
195
HOLLY C.
/RC120
1073 500 542 140 80 300
3.3
-
11.83
0.75
-
2.64
110
230
-
50
25
9.6
-
41
85
-
89.4
0.013
-
0.028
4.81
-
8.60
0.1
-
10
121
-
281
HOLLY V.
/RV120
1073 500 542 140 80 300
2.9
-
11.92
0.66
-
2.8
120
231
-
50
25
8.4
-
42
86.9
-
90.5
0.014
-
0.028
4.57
-
8.40
0.1
-
10
114
-
265
LISA
PLUS
960 450 480 90 80 150
3.3
-
7
0.5
-
1.6
100
230
-
50
15
9.3
-
30
>90
0.015
-
0.020
4.24
-
5.14
0.1
-
10
113
-
188
MAVÌ
1080 575 590 85 80 150
2.9
-
5.5
0.65
-
1.31
100
230
-
50
15
9.3
-
30
89
0.017
-
0.019
3.37
-
4.93
0.1
-
10
121
-
171
MILENA
1100 550 540 140 80 230
2.5
-
12
0.5
-
2.5
110
230
-
50
31
12.4
-
62
87
0.03
-
0.04
9.4
-
11.3
0.1
-
10
103
-
209
MONICA
1003 513 457 92 80 205
2.8
-
8.5
1.8
-
0.5
110
230
-
50
15
8.3
-
30
>85
0.020
-
0.040
0.29
-
0.81
0.1
-
10
153
-
195
OLIVIA
1130 800 250 100 80 170
3.3
-
7.1
0.72
-
1.67
110
230
-
50
20
12
-
28
92
0.031
-
0.023
4.19
-
7.77
0.1
-
10
97
-
174
R70
951 440 450 92 80 150
2.5
-
7.5
0.5
-
1.6
100
230
-
50
15
9.3
-
30
>85
0.019
-
0.040
0.29
-
0.76
0.1
-
10
153
-
185
RC70
951 440 491.5 95 80 210
2.5
-
8
0.5
-
1.7
340
230
-
50
13
8
-
26
87.5
-
87.5
0.020
-
0.040
0.29
-
0.76
0.1
-
10
153
-
185
RV80
986 512 484 90 80 195
2.99
-
8.02
0.68
-
2
110
230
-
50
15
9
-
21
81.85
-
89.60
0.014
-
0.032
3.42
-
7.74
0.1
-
10
120
-
226
RV100
1099 524 532 130 80 240
2.8
-
10
2.2
-
0.6
110
230
-
50
25
10.5
-
42
87.5
-
91
0.012
-
0.029
3.8
-
7.4
0.1
-
10
83
-
189
RV110
1115 552 606 145 80 265
3.1
-
10.5
0.7
-
2.2
280
230
-
50
22
10
-
31.5
93
-
88
0.017
-
0.027
3.8
-
7.4
0.1
-
10
83
-
189
R1000
790 587 446 97 80 240
2.5
-
10
0.5
-
2.1
110
230
-
50
13
4.5
-
18
>87
0.022
-
0.028
4.6
-
8.31
0.1
-
10
130
-
219
RC1000
627 753 591 106 80 230
3
-
9.5
0.6
-
2
110
230
-
50
15
6.3
-
25
>87
0.016
-
0.017
9.3
-
9.4
0.1
-
10
119
-
211
SNELLA
1158 817 364 140 80 270
3.5
-
11
0.7
-
2.5
110
230
-
50
30
12
-
43
>85
0.015
-
0.053
5.3
-
10
0.1
-
10
63
-
124
SOFIA
949 635 585 196 80 300
3.3
-
12
2.6
-
0.7
110
230
-
50
20
7
-
30
>86
0.015
-
0.017
6
-
9.6
0.1
-
10
118
-
196
SPILLO
770 710 650 220 80 320
3.5
-
12.5
2.6
-
0.7
110
230
-
50
20
7
-
30
>86
0.015
-
0.016
6
-
9.5
0.1
-
10
118
-
195
The data shown above are indicative and not binding. Ravelli reserves the right to make
any modifications for the purpose of improving the performances of the product. For
any information related to the dimention and weigth of the stove, please refer to the
dedicated leaflet.
Fig.11
Protection from rain
Insulated ue
Union tee for condensation
Fig.9
YES