Operation Manual

Pag.22
that the user want a room temperature
of 21°C and to reach this temperature
he sets a working power of 3. The pas-
sages to do will be the following:
From the MENU CHRONO confirm
with key OK and set the program you
want to modify using key 1 and 2;
By confirming with key OK you go to
the set of the switch on hour, set the
hour (hh:mm) using keys 1 and 2;
By confirming with key OK you go to the set of the switch off hour, set the hour
(hh:mm) using keys 1 and 2;
By confirming with key OK you go to the scroll of the days, with keys 1 and 2
activate/deactivate the days (ex: Monday, Tuesday, Wednesday, Thursday and
Friday active).
By confirming with key OK you go to the set of the power, with keys 1 and 2 set
the value (ex: Power 3).
By confirming with key OK you go to the set of the room temperature, with keys 1
and 2 set set the degrees (ex: 20°C).
When the stove is working and the set room temperature is reached the stove
goes into MODULATION or COMFORT CLIMA (if activated).
!!
BY USING THIS MODE IT IS NECESSARY TO CHECK THAT
AFTER EVERY AUTOMATIC SWITCHING OFF THE FIREPOT
IS ALWAYS WELL CLENAED IN ORDER TO GUARANTEE A
PERFECT AUTOMATIC IGNITION.
7.2.6 Menu “LANGUAGE“
To enter in the USER MENU press two times key OK.
To enter in the menu “SET LAN-
GUAGE” press 5 times key 2 and
con rm with OK. To select language
please use keys 1 and 2. By last con-
rmation with OK you save all settings
and return automatically to the screen
with the icons. To return to the main
screen press at the same time keys
1 and 2. Alternatively it is possible to
exit by step from the menus by press-
ing each time the key OK.
7.2.7 Menu “CONFORT CLIMA“
To enter in the USER MENU press two times key OK.
To enter in the menu “COMFORT CLIMA” press 6 times key 2 and con rm with
OK. To modify the settings use keys
1 and 2 and by pressing OK you con-
rm the data and go on to the follow-
ing one. By last con rmation with OK
you save all settings and return auto-
matically to the screen with the icons.
To return to the main screen press at
the same time keys 1 and 2. Alterna-
tively it is possible to exit by step from
the menus by pressing each time the
key OK.
7.2.8 Mode “SILENCE“
To enter in the USER MENU press two times key OK.
To enter in the MODE SILENCE press 7 times key 2 and con rm with OK.
Enable or disable the function by using key OK. To return to the main screen
press at the same time keys 1 and 2. Alternatively it is possible to exit by step
from the menus by pressing each time the key OK.
7.2.9 Mode “SELF CONTROL SYSTEM“
To enter in the USER MENU press two times key OK.
To enter in the MODE S.C.SYSTEM press 8 times key 2 and confirm
with OK. Enable or disable the function by using key OK. To return to
the main screen press at the same time keys 1 and 2. Alternatively it
is possible to exit by step from the menus by pressing each time the
key OK.
7.2.10 Menu “VIEW SETTINGS“
In this menu you can verify the pa-
rameters set in the motherboard.
To enter in the USER MENU press
two times key OK.
To enter in the menu “VIEW SET-
TINGS” press 9 times key 2. By
confirming with OK you enter in the
list of set parameters. To scroll the
list of parameters use key 1 and 2.
To return to the main screen press
at the same time keys 1 and 2.
Alternatively it is possible to exit by step from the menus by pressing each
time the key OK.
7.2.11 Menu “VIEW WORKING HOURS“
In the menu VIEW WORKING HOURS you can check the total or par-
tial working hours and also the number of ignitions of the stove. It is
possible sometimes that the work-
ing hours are not reset and you see
numbers like 5000/15000/25000. It
will be care of the technician to re-
set these numbers by first ignition.
This does not means that the stove
has already worked for so many
hours, it is just a setting made dur-
ing the tests we make in Ravelli,
before the stoves are packed and
delivered. This menu is used by the
After Sales Center to evaluate the total working hours of the stove during
the season and consequently to evaluate the need of cleaning (“service
hours”). To enter in the USER MENU press two times key OK. To enter in
the menu “VIEW WORKING HOURS” press 10 times key 2. By confirm-
ing with OK you see the working hours of the stove. To scroll the different
counters (total or partial hours and number of ignitions) use key 1 and
2. To return to the main screen press at the same time keys 1 and 2. Al-
ternatively it is possible to exit by step from the menus by pressing each
time the key OK.
SERVICE HOURS
All our models need in addition to the regular cleaning (reference to the
paragraph dedicated to the maintenance of the stove in the user manual),
also a special cleaning which should be done by the installer (author-
ized by the producer). At the time of the installation it is possible to set
a number of working hours appropriate for the model following this pro-
cedure default settings>>extra parameters>>TF53 service hours. At the
end of these hours on the display will appear the message “SERVICE
HOURS” followed by an acoustic signal. When this message appears
please contact the installer to do the special cleaning of the stove. If the
cleaning is not done the message will appear by each ignition but will not
interrupt the functioning of the stove.
.
7.2.12 Menu “SET AIR/PELLET“
The set of the draught-pellet blend
allow to modify immediately the
quantity of inlet air and the quantity
of pellet loaded in the firepot. The
stove is tested with pellet certified
DIN PLUS. If you do not use certi-
fied pellet could be necessary to set
the combustion. Normally the modi-
fication is made on the “% FLUX” to
adjust the inlet air and consequent-
ly the combustion; if the regulation
of the flux is not sufficient could be
necessary to adjust also the “% PELLET”.
!!
BY USING THIS MODUS IT IS NECESSARY TO CHECK THAT
AFTER EVERY AUTOMATIC SWITCH OFF THE FIREPOT
IS CLEANED IN ORDER TO GUARANTEE A CORRECT
AUTOMATIC SWITCH ON.
8. DESCRIPTION OF THE FUNCTIONS
8.1. The modulation
During the working phase the stove has to reach the set room tempera-
ture; once the set temperature is satisfied, the stove goes into MODULA-
TION WORK, dutring which the consumption of pellet is minimum and the
room fan works at minimum power.