99% up to Efficiency! Can be vented with PVC MBTU Models 300 • 400 • 500 • 700 • 850 CSA Verified lead Content Less Than .
Xtreme Outdoor Performance Up to 99% part load! XFyreT Condensing Modulating Boiler - The Green Choice Raypak’s new XFyreT is a natural extension of our successful XThermT modulating vertical boiler line (1,1.5, 2 Million BTUH). Raypak offers new features not found in other mod-con style boilers and combines these desirable features into one complete boiler package. XFyre is the only condensing boiler (300 to 850MBTUH) with CSA outdoor certification.
Model 850 1. Water Inlet As low as 50°F entering. All copper and brass factory installed vertical plumbing connections. Vertical plumbing allows boilers to be installed side by side or in tight places if need be. Male NPT connections. 2. Water Outlet All copper and brass factory installed vertical plumbing connections. Male NPT connections. 3. Low Voltage Wiring Board Allows easy front access to thermostat connections, Outdoor sensor, DHW sensor, Alarm contacts and BMS input signal (0-10VDC).
Xtreme Access The XFyre is purpose built for the contractor and service professional. 7 4 8 Completely serviceable from the front, top and both sides! 1. Flue Outlet Category IV- PVC, CPVC and Stainless steel certified. The XFyre ships PVC ready, no extras to purchase! 2. High Voltage Wiring Box 120VAC main incoming power connections. Boiler pump wiring and DHW pump wiring. Alarm power out. 3. Gas Inlet The XFyre will operate at 100% full rate with gas pressures as low as 4.0”w.c. 4.
Xtremely Small Footprint Dimensions (in.) Model 300 400 500 700 850 A Length E 28 - 1/4 30 - 3/4 37 - 1/4 47 - 3/4 54 - 1/4 16 - 1/2 16 - 1/2 16 - 1/2 28 28 F Mounting G NPT H NPT 27 - 9/16 29 - 3/4 36 - 1/4 47 - 1/16 53 - 9/16 3/4 1 1 1 - 1/4 1 - 1/4 1 - 1/2 2 2 2 2 V Ship Weight (lbs.) FootPrint (ft2) Amps* Flue Ø T C/A Ø 4 4 4 6 6 4 4 4 6 6 3 3 3 19 - 3/8 19 - 3/8 410 465 505 550 580 4.3 4.7 5.7 7.3 8.3 3 4 4 5 5 K Ratings shown are for elevations up to 10,000 feet.
Xtremely Easy to Wire 120VAC Wiring Center The XFyre’s 120VAC wiring center is located on the rear of the boiler. All incoming line voltage and pump wiring are contained away from the 24v control wiring. Wiring the boiler is simple and straight forward. Low Voltage Wiring Center Just like its big brother the XTherm, the XFyre has a separate front mounted wiring center for all of the low voltage connections. This makes thermostat, water sensor, 0-10VDC BMS, and alarm contacts a breeze to set up.
Xtreme Control Boiler Control and On-Board Diagnostic Center Raypak’s XFyre comes equipped with a microprocessor control center that displays its information on a 2x20 character LCD display in plain English. All set-up and programming is done at this interface. Control monitors boiler system status including safeties, ignition faults and also stores up to 10 reported faults. The diagnostic center even monitors and reports the flame strength signal in microamps.
Water Heaters (Type WH) Boilers (Type H) ASME Section IV, National Board Registered, 160 PSI • H Stamp v v Heat Exchanger Tubes • 316L Stainless Steel v v Stainless Steel • CSA Verified AB-1953 CA low lead compliant v v Pressure Relief Valve (loose) • 60 PSI • 125 PSI • 30, 45, 75, 150 PSI V v V v V v V V v V Fully-Enclosed Controls Combustible Floor Rated v V V v v v V V v v 120V Power Supply On/Off Switch Programmable Pump Time Delay, Single-Phase Terminal Block Connections (Front moun