User`s manual

DIGITAL󰚟INCUBATOR
9
SET UP(Other Functions)
Easy Function Operation
1. Introduction
REFER TO "HOW TO START INCUBATION" FOR MORE INFORMATION.
(6) SET UP(Other Functions) /
Easy Function Operation
1. Introduction
(6) SET UP(Other Functions) /
Easy Function Operation
How󰚟to󰚟Oper ate
Function
Page
12
17
17
17
16
16
16
13
󰛽
15
Egg Turning Test
Setting Value
Check
5 Sec.
ENTER ENTER
UP
DOWN
"All Reset"
SET󰚟UP
BACK
ENTER
ENTER
SET󰚟UP
BACK
UP
DOWN
UP
DOWN
UP
DOWN
UP
DOWN
℃↔℉
ENTER
ENTER
MANUAL
ENTER
2 Sec.
Select
the Species of Bird
"OFF"
4 times
MANUAL
DOWN
ENTER
Screen
on Incubation
UNDER 30%
Automatic Mode
Incubation
Other(Manual) Mode
Incubation
How to change Setting
under Incubation
Incubation
Termination
Incubator Initialization
(Factory Setting)
How to change
How to turn off
Humidification Function
󰚟In case of low humidity
incubation
MENU
ENTER
System finish
Are you sure?
Screen
on Incubation
Select YES
MANUAL
ENTER
Once: Temp. Setting
4 times: Humidity Setting
7 times:
Egg Turning Angle Setting
9 times: Egg Turning Interval Setting
MENU
ENTER
ENTER
UP
DOWN
Select
the Species of Bird
Temp. Setting
Humid. Setting
Egg Turning Angle Setting
Egg Turning Interval Setting(Incubation day)
Info
ALL󰚟RESET
󰚟󰚟ALL󰚟RESET
Factory setting
Alarm sounds when incubator temp. is higher than setting value
because of room temp. change or heating system disorder
*󰚟Setting Range : 0.0󰚟~ 5.0 (Default Setting : 2.0)
Alarm sounds when incubator temp. is lower than setting value
because of room temp. change or heating system disorder
* Setting Range : 0.0󰚟~ -5.0 (Default Setting : -3.0)
Uni t
A LA RM
󰚟Abnomal
High Alarm
A LA RM
Abnomal
low Alarm
Hi gh
T emp
Hi Er r
Low
T emp
LoEr r
Sound
Li ght󰚟
*󰚟Always On : Always BackLight On
*󰚟Event On : 20 Sec. ON with Key input
*󰚟Always Off : Always BackLight Off
* Default Value : Always On
LCD Backlight management setting
It returns to factory setting when you change the initial setting at discretion.
ON/OFF Setting for Melody, other alarms
* Default Value : ON
Basic information of Incubator (versoin Indication)
T.CAL
Temperature
Calibration
Selecting Centigrade (
o
C) and Fahrenheit (
o
F)
*󰚟Default Value : Centigrade (
o
C)
H.CAL
󰚟 Humidity
Calibration
Temp. calibration limits : -9.9 ~ +9.9
Be sure to read CAUTIONS. ( Calibration available after 5 Sec. )
H
um
i
d
i
t
y
c
a
l
i
b
r
a
t
i
on
l
i
m
i
t
s
:
-
2
0%
~
+2
0%
Be sure to read CAUTIONS. ( Calibration available after 5 Sec.)
WARNING
Fatal Damage
with Incorrect Calibration
WARNING
Fatal Damage
with Incorrect Calibration