Instructions / Assembly

7
3 - RESIDENTIAL APPLICATIONS - WOOD FRAMING
3.1 Typical Residential Wall
Application Method A
1. Measure working area where
Reective Air will be applied.
2. Fasten the Reective Air to the stud
facing using 1/2” staples every 4” - 6”.
3. The white polyethylene side of the
Reective Air should be facing the
mass insulation.
4. Apply 1 x 3 strapping running
horizontally (at 16” on centre) to the
Reective Air, running the length of
the wall.
5. Ensure that all seams are securely taped using reective tape.
6. Fasten the interior nish to the strapping using approved construction methods.
NOTE: This installation method will decrease sound transmission
3.2 Typical Residential Wall
Application Method B
1. Apply 1 x 3 strapping running
horizontally (at 16” on centre) to the
stud facing, running the length of
the wall.
2. Measure working area where
Reective Air will be applied.
3. Fasten the Reective Air to the stud
facing using 1/2” staples every 4” - 6”.
4. Ensure that all seams are securely
taped using reective tape.
5. Apply 1 x 3 strapping running vertically (at 16” on centre) on top of the Reective Air,
running the length of the wall.
6. Fasten the interior nish to the strapping using approved construction methods.
EXTERIOR FINISH*
6” MASS INSULATION
STRAPPING HORIZONTAL
1”x3” AT 16” O.C.
AIRSPACE
SHEATING AND
AIR BARRIER
INTERIOR FINISH
Reflective Air
TAPE ALL SEAMS
EXTERIOR FINISH*
6” MASS INSULATION
STRAPPING HORIZONTAL
1” x 3” AT 16” O.C.
AIR SPACE
INTERIOR FINISH*
TAPE ALL SEAMS
SHEATING AND
AIR BARRIER
*According to Wall Design
Reflective Air