SDS

Safety Data Sheet
According to HCS-2012 APPENDIX D TO §1910.1200
Fluorescent material
Jiangsu TÜV Product Service Ltd. Guangzhou Branch Technical Report No.: 64.165.13.03963.01
TÜV SÜD Group
5F, Communication Building, 163 Pingyun Rd, Huangpu West Ave. Engineer: Echo He
Guangzhou 510656 P.R. China 2013-12-23
Tel.: +86 20 3832 0668, Fax: +86 20 3832 0478 Page 3 of 9
6. Accidental release measures
(a) Personal precautions, protective equipment and emergency procedures
Handle in accordance with good industrial hygiene and safety practice.
(b) Methods and materials for containment and cleaning up
For large amounts: Transfer product into suitable containers.
For residues: Pick up with suitable absorbent material (e.g. sand, sawdust, general-
purpose binder, kieselguhr). Dispose of absorbed material in accordance with regulations
7. Handling and storage
(a) Precautions for safe handling
Ensure thorough ventilation of stores and work areas.
(b) Conditions for safe storage, including any incompatibilities
Further information on storage conditions: Containers should be stored tightly sealed in a
dry place.
8. Exposure controls/personal protection
(a) Control parameters
OSHA
NIOSH
Component
PEL
-
TWA
PEL
-
STEL
REL
-
TWA
REL
-
STEL
131-11-3 5 mg/m3 Not Established 5 mg/m3 Not Established
136-60-7
Not Established Not Established Not Established Not Established
75203-51-9 Not Established Not Established Not Established Not Established
7722-84-1 1.4 mg/m3 Not Established 1.4 mg/m3 Not Established
7732-18-5 Not Established Not Established Not Established Not Established
10075-85-1 Not Established Not Established Not Established Not Established
(b) Appropriate engineering controls
Provide local exhaust ventilation system. Ensure compliance with applicable exposure
limits.
(c) Personal protective equipment
Respiratory protection: The following respirators and maximum use concentrations
are drawn from NIOSH and/or OSHA.
50 mg/m3
Any air-purifying full-facepiece respirator equipped with an
N95, R95, or P95 filter. The following filters may also be used:
N99, R99, P99, N100, R100 or P100.
125 mg/m3