SDS

FIRE FIGHTING MEASURES-SECTION 5
NFPA Classification
Health Fire Reactivity Other
1 3 0 N/A
Flash Point:
Over 78
o
F
Method:
N/A
Flammability
Limits:
Nonflammable
aqueous
solution
LEL:
N/A
UEL:
N/A
Firefighting Instructions:
If package is opened, the contents will burn.
Handle as flammable liquid
Extinguishing Media:
Alcohol resistant foam, Carbon dioxide for
small fires.
Firefighting Equipment:
Wear self-contained breathing apparatus and
full protective gear. Treat as combustible.
ACCIDENTAL RELEASE MEASURES-SECTION 6
If package is damages, treat as flammable and remove sources of ignition. Pick up and place in
disposal container. If packaging is intact, product may be used before discarding.
HANDLING & STORAGE-SECTION 7
Keep away from heat sources. Keep container closed when not in use. Store in cool, well
ventilated area, out of direct sunlight, and away from incompatible materials.
EXPOSURE CONTROLS/ PERSONAL PROTECTION-SECTION8
Exposure Limits:
8hours
TWA ACGIH TLV:
Isopropanol 400ppm
TWA OSHA PEL:
Isopropanol 400ppm
Engineering Controls:
Local exhaust ventilation acceptable
Protective Clothing or Equipment:
None required
PERSONAL PROTECTIVE EQUIPMENT
None required
Eye / Face Protection:
Eye protection, as necessary to prevent
excessive contact.
Skin protection:
None required under normal conditions.
Respiratory protection:
None required under normal conditions.
Safety Data Sheets (SDSs)
GFA-SDS-061
2015-2-27