Assembly Instructions

HANGING INSTRUCTIONS
STEP 3
1 Taking the chain, determine the length you require to hang the fixture.
2 Attach one end of the chain to the top loop of the fixture - see Drawing 2.
3 Now slip loop collar (6) and canopy (B) onto chain (C).
4 Attach other end of chain to loop (5). Get assistance for this step since fixture
may be heavy and difficult to hold while attaching the chain.
[DRAWING 1]
[DRAWING 2]
1
2
A
4
B
5
C
6
weave supply wire and
ground wire through chain
GS
3c
3b
3a
half of threaded area
exposed
1 Fasten mounting strap (1) to outlet box (A) with the two 8-32 screws (not provide)
(2) -see Drawing 1.
2 Thread 2 - hex nuts (3a) and (3b) onto threaded tubing (4).
3 Thread one end of threaded tubing (4) into loop (5) a minimum of 1/2” to 3/4”.
Thighten hexnut (3a) against loop (5) to lock loop in position.
4 Thread other end of threaded tube (4) into mounting strap approximately 1/2”.
5 Slip canopy (B) over loop (5) and adjust height of loop so half of the threaded area
on the loop is exposed - see Drawing 2 below. After loop height is adjusted, thigten
hex nut (3b) up against mounting strap, tighten against mounting strap to lock
in position.
6 Remove mounting strap (1) from junction box (A), and thread third hex nut (3c) onto
end of threaded tube (4), above the mounting strap (1), tighten against mounting strap
to lock assembly in position.
7 Remount mounting strap to junction box.
STEP 4
1 Unwrap supply wire and ground wire and weave them up through the chain.
2 Slip supply wire and ground wire through center of loop (5).
3 Connect ground wire to mounting strap (1) using green ground screw (GS).
4 Make electrical connections from supply wire to fixture lead wires. Refer to
instruction sheet and follow all instructions to make all necessary wiring
connections.
5 Slip canopy up firmly against the ceiling and secure by turning the threaded
loop collar (6) onto loop (5) until tight.
SAFETY WARNING: Read wiring and grounding instructions
and any additional directions. Turn power supply off during installation. If new
wiring is required, consult a qualified electrician or local authorities for code
requirements.
STEP 1
1 Shut off electrical current before starting. If the fixture you are replacing is
turned on and off by a wall switch, simply turn the switch off. If not, remove the
appropriate fuse (or open the circut breakers) until the fixture is dead.
• DO NOT restore current - either by fuse, breaker or switch - until the new
fixture is completely wired and in place.
STEP 2