Black Shading calibration of the MYSTERIUM X sensor two (2) different ways; Default (at 24 FPS @ 1/48
SEC) or using your current FPS/Exposure settings.
To calibrate the sensor the image needs to be as dark as possible:
At a minimum put a lens cap on the lens (WARNING: Not all lens-caps completely block IR. They are
made to protect the lens, not necessarily to block light...)
Preferably, take of the lens, and use the lens-mount cap provided by RED.
If possible, use a dark room.
Just closing the Iris is NOT sufficient.
Additionally a SSD needs to be inserted in the camera to store the raw images during calibration.
Calibration is required:
If the temperature deviates significantly from the currently used calibration, it is recommended to
recalibrate the sensor.
If very long exposure (~longer then 1/24 Sec) is used it is recommended to recalibrate.
After Calibration with a lens cap on and ISO set to maximum, the sensor should show a uniform noise
profile over the whole area without any falloffs on any side. You can check at which
temperature/exposure time the currently used calibration was taken on under SETTINGS >
MAINTENANCE > SYSTEM STATUS under Calibration.
Calibration maps will still be available after performing a system restore under SETTINGS >
MAINTENANCE > RESTORE SYSTEM; however the factory calibration map will be reselected.