Operation Guide

955-0002_v3.3, Rev-B COPYRIGHT © 2012 RED.cm, Inc.
143 143
BLACK SHADING PROCEDURE
The calibration procedures are the same for both BLACK SHADING options.
The calibration procedures are the same for both Black Shading (24 FPS @ 1/48 SEC) and Black
Shading (Current FPS/Exposure) options.
When selected, a screen will appear asking if you wish to proceed with Black Shading calibration.
REDMOTE will also display the following messages.
Black Shading calibration procedure:
1. Ensure the sensor is NOT exposed to the calibration light source by installing the lens cap properly.
2. Ensure a properly formatted SSD is attached to the camera and properly formatted.
3. Select OK to perform the Black Shading calibration. The calibration will make 2 passes.
4. A status screen will show progress of the Capturing step. Second pass shown.
5. Once Capturing is complete, a status screen will show progress of the Analyzing step.