Product Brochure

Weatherproof metallic covers
Code Keeper
®
metallic while-in-use covers
Cover
Hinge
Plate
FS mount
Device mount
Padlock eye for
1
4
" shackle
4 Red•Dot weatherproof boxes & covers | Catalog
Applications:
Protects receptacles, switches and plugs for single-gang and
two-gang configurations in dry and wet locations
Provides a lockable cover that complies with OSHA lockout/
tagout requirements
Prevents accidental equipment disconnects, reduces
tampering and deters theft and equipment removal
Features/Benefits:
Alloy A360 copper-free* aluminum provides increased
corrosion resistance
Die-cast, metal construction provides long-lasting durability
NEMA 3R Rating ensures protection against falling rain,
sleet and external ice formation when used with appropriate
device boxes
Clear UL
®
and CSA markings speed approval by inspectors
Wide range of cover depths and receptacle configurations
accommodate almost every common plug and cord size
when combined with included adapter plates
Combination box or device mounting design provides
flexibility in installation
Standard materials:
Covers and plates: Die-cast aluminum alloy A360 with less
than .004 copper content (copper-free)
Gaskets: Closed-cell foam
Standard finish:
Powder-coated finish
Compliances:
NEC
®
Section 406.9(B)
UL
®
Listed
CSA Certified
NEC and National Electrical Code are registered trademarks of the National Fire Protection
Association, Inc.
Sample specifications:
Code Keeper
®
covers shall comply with NEC
®
Section
406.9(B) and be die-cast copper-free* aluminum alloy A360.
Covers shall be finished powder-coated paint.
Red•Dot
®
Catalog No. _______________
*Less than .004 copper content.
All 15- and 20-ampere, 125- and 250-volt receptacles installed
outdoors in a wet location must have an enclosure that is
weatherproof whether or not the attachment plug is inserted.
Code-Keeper
®
is required by the National Electrical Code
®
Section 406.9(B) for unattended in-use plugs in wet locations.
Die-cast A360 aluminum alloy (less than .004% copper
content)
NEMA 3R Rating
Clear UL
®
and CSA markings
Wide range of cover depths and receptacle configurations
Sturdy lockable cover tab complies with OSHA lockout/
tagout requirements
Combination box- or device-mount design (for most styles)
Powder-coated finish
“Extra-Duty” per NEC
®
Section 406.9(B)(1)
CKSUV
Single-gang
small vertical
CKMU
Single-gang
medium horizontal
CKLSVU
Single-gang
large vertical
CKMUV
Single-gang
medium vertical
2CKU
Two-gang