H-60
Rigid/Aluminum Conduit Bodies, Gaskets and Covers
CE
T
LL, LR & LRL
Open
Thru
SIZE DIMENSIONS (IN.)
(IN.) A B C D E F G CI
1
⁄2 3
7
⁄8 4
3
⁄8 11
3
⁄8 2
13
⁄32 2
1
⁄16
13
⁄16 4.3
3
⁄4 4
5
⁄8 5
1
⁄8 1
17
⁄32 1
5
⁄8 2
25
⁄32 2
11
⁄32
15
⁄16 7.3
15
3
⁄8 5
15
⁄16 1
3
⁄4 1
7
⁄8 3
1
⁄2 2
5
⁄8 1 11.8
1
1
⁄4 7
1
⁄4 7
7
⁄8 2
1
⁄2 2
1
⁄2 4
3
⁄16 3
17
⁄32 1
3
⁄8 32.0
1
1
⁄2 7
1
⁄4 7
7
⁄8 2
1
⁄2 2
3
⁄4 4
3
⁄16 3
17
⁄32 1
1
⁄2 32.0
29
1
⁄2 10
3
⁄16 3
1
⁄8 3
9
⁄16 5
13
⁄32 4 1 69.5
2
1
⁄2 12
1
⁄4 13 4
1
⁄2 4
1
⁄2 6
7
⁄8 5
25
⁄32 2
7
⁄16 190.0
312
1
⁄4 13 4
1
⁄2 4
1
⁄2 6
7
⁄8 5
25
⁄32 2
7
⁄16 190.0
3
1
⁄2 15 16
5
⁄16 5
1
⁄2 5
9
⁄16 8
13
⁄16 6
13
⁄16 3 366.0
41516
5
⁄16 5
1
⁄2 5
9
⁄16 8
13
⁄16 6
13
⁄16 3 366.0
LB
SIZE DIMENSIONS (IN.)
(IN.) A B C D E F CI
1
⁄2 3
7
⁄8 4
9
⁄32 1
5
⁄16 1
5
⁄16 3
1
⁄2 2
1
⁄16 4.3
3
⁄4 4
5
⁄8 5
1
⁄8 1
17
⁄32 1
5
⁄8 4
1
⁄4 2
7
⁄16 7.3
15
3
⁄8 5
15
⁄16 1
3
⁄4 1
7
⁄8 4
15
⁄16 2
3
⁄4 11.8
1
1
⁄4 7
1
⁄4 7
7
⁄8 2
1
⁄2 2
1
⁄2 6
1
⁄2 3
9
⁄16 32.0
1
1
⁄2 7
1
⁄4 7
7
⁄8 2
1
⁄2 2
3
⁄4 6
5
⁄16 3
13
⁄16 32.0
29
1
⁄2 9
13
⁄16 3
1
⁄8 3
7
⁄16 84
1
⁄2 69.5
2
1
⁄2 12
1
⁄4 13 4
1
⁄2 3
7
⁄8 10
27
⁄32 5
1
⁄4 190.0
312
1
⁄4 13 4
1
⁄2 4
1
⁄2 10
1
⁄2 5
7
⁄8 190.0
3
1
⁄2 15 16
5
⁄16 5
1
⁄2 5
9
⁄16 13
1
⁄2 6
15
⁄16 366.0
41516
5
⁄16 5
1
⁄2 5
9
⁄16 13
1
⁄2 6
15
⁄16 366.0
Conduit Body Wiring Table* — Style of Fitting
TRADE SIZE (IN.) LB C T LL, LR, LRL
3
⁄4 #6 #6 #6 #6
1#4#4#4#4
1
1
⁄4 #2 #2 #2 #2
1
1
⁄2 1/0 1/0 #1 1/0
2 4/0 2/0 1/0 4/0
2
1
⁄2 300 kcmil 250 kcmil 2/0 300 kcmil
3 400 kcmil 250 kcmil 2/0 500 kcmil
3
1
⁄2 500 kcmil 350 kcmil 250 kcmil 500 kcmil
4 500 kcmil 350 kcmil 250 kcmil 500 kcmil
*The maximum number and size of wire that can be safely pulled is based
on three type-XHHW wires or equal.
SIZE DIMENSIONS (IN.) LRL STYLE
(IN.) A B C D E F G H CI CI ONLY
1
⁄2 3
7
⁄8 3
1
⁄2 4
5
⁄16 1
5
⁄16 1
3
⁄8 3
9
⁄16 2
25
⁄32 4.3 4.8 —
3
⁄4 4
5
⁄8 4
1
⁄8 5
1
⁄8 1
17
⁄32 1
5
⁄8 4
1
⁄8 2
5
⁄16
7
⁄8 7.3 7.5 —
15
3
⁄8 4
7
⁄8 5
5
⁄16 1
3
⁄4 1
7
⁄8 4
7
⁄8 2
1
⁄2 1 11.8 12.5 —
1
1
⁄4 7
1
⁄4 6
1
⁄2 7
7
⁄8 2
1
⁄2 2
3
⁄4 6
5
⁄16 3
3
⁄8 1
1
⁄2 32.0 36.5 —
1
1
⁄2 7
1
⁄4 6
1
⁄2 7
7
⁄8 2
1
⁄2 2
3
⁄4 6
5
⁄16 3
3
⁄8 1
1
⁄2 32.0 36.5 —
29
1
⁄2 8
9
⁄16 10
3
⁄16 3
1
⁄8 3
7
⁄16 8
3
⁄16 3
15
⁄16 1
15
⁄16 69.5 73.8 —
2
1
⁄2 12
1
⁄4 11
1
⁄4 13 4
1
⁄2 4
1
⁄2 10
1
⁄4 5
1
⁄2 2
7
⁄8 190.0 — —
312
1
⁄4 11
1
⁄4 13 4
1
⁄2 4
1
⁄2 10
1
⁄4 5
1
⁄2 2
7
⁄8 190.0 — —
3
1
⁄2 15 14
7
⁄16 16
1
⁄4 5
1
⁄2 5
1
⁄2 12
3
⁄4 6
1
⁄2 3 366.0 — —
41514
7
⁄16 16
1
⁄4 5
1
⁄2 5
1
⁄2 12
3
⁄4 6
1
⁄2 3 366.0 — —
LL LR LRL
A
B
C
F
C
E
G
D
A
C
B
D
F
E
A
B
D
G
C
F
H
E
C, E and T
LL, LR and LRL
C, E & T
and
Weatherproof Boxes, Covers and Conduit Bodies