DataDirect Networks SFAOS 2.2.1.3 Release Notes Revision A1 | 6
Figure 1
$ show enclosure
************************
* Enclosure(s) *
************************
Idx|Pos|Type |Logical ID |Vendor ID| Product ID|Revision|
--------------------------------------------------------------------------
0 NA CONTROLLER 0x0001ff0900160000 DDN SFA12000 0000
1 3 DISK 0x50001ff211320000 DDN SS7000 0502
2 2 DISK 0x50001ff2114be000 DDN SS7000 0502
3 5 DISK 0x50001ff2114ce000 DDN SS7000 0502
4 1 DISK 0x50001ff21156a000 DDN SS7000 0502
5 4 DISK 0x50001ff2114ba000 DDN SS7000 0502
6 NA CONTROLLER 0x0001ff0900100000 DDN SFA12000 0000
Total Enclosures: 7
2. For each enclosure Idx (Index) number showing ‘Type’ value of “Controller” (there
should be two), issue 'SHOW ENCLOSURE <x> ALL' to identify your current BMC
version. For the output in Figure 1, you would use 'show enclosure 0 all' and
'show enclosure 6 all'. Example output for 'SHOW ENCLOSURE 0 ALL' is
shown in Figure 2.
Figure 2
$ show enclosure 0 all
************************
* Enclosure(s) *
************************
Index: 0
Enclosure: 0x50000000
Type: CONTROLLER
Logical ID: 0x0001ff0900160000
Vendor ID: DDN
Product ID: SFA12000
Revision: 0000
Is Responsive: TRUE
Fault Status: OK
Child Fault Status: NON-CRITICAL
Zones: 0
Zoning Configuration: 0
Position: NOT APPLICABLE
Fault Indicator: OFF
Predicted Failure Ind: OFF
Locate Indicator: OFF
Baseboard part number: X9DRX+-F-DD007
Baseboard serial number:WM21S31110
Baseboard date: 19960101
BIOS version: 21.0k
BMC version: 21.67
Firmware version: 1.5.1.2
Total Enclosures: 1
3. After the firmware is updated, the controller will reboot. As it performs the system
check, it will check the ICL firmware version. If the ICL firmware version is older than
the versions shown below, the SFA will automatically update the ICL of the local
controller, and then it will reboot again.