Installation manual

Regency I2400M
15



The gold electroplated nish on the doors requires
little maintenance, and need only be cleaned with
a damp cloth. DO NOT use abrasive materials or
chemical cleaners, as they may harm the nish
and void the warranty.

If the door gasket requires replacement, 7/8"
diameter material must be used. A proper high
temperature gasket adhesive is required. A gasket
repair kit, Part # 846-570 is available from your
local Regency dealer.


The door latch may require adjustment as the
door gasket material compresses after a few
res. Removal of the spacer washer, shown in the
diagram below, will allow the latch to be moved
closer to the door frame, causing a tighter seal.
Remove and replace the nuts, washer as shown.

Only clean your glass window when it is cool.
Your local retailer can supply you with special
glass cleaner if plain water and a soft cloth does
not remove all deposits.

Your Regency Insert is supplied with 5 mm.
Neoceram ceramic glass (Part #846-304) that
will withstand the highest heat that your unit will
produce. In the event that you break your glass
by impact - purchase your replacement from an
authorized Regency dealer only, and follow our
step-by-step instructions.



Allow the stove to cool before removing or replacing
glass. Remove the door from the insert and remove
the glass retainer. Use caution when removing
broken glass to prevent injury.
When placing the replacement glass in the door,
make sure that the glass gasketing will properly seal
your unit. Replace the retainer and tighten securely,
but do not wrench down on the glass as this may
cause breakage. Do not substitute materials. If your
glass door does break, do not continue to use your
unit until it has been replaced.
Annual Maintenance
Completely clean out entire unit Annually
Inspect air tubes, baffles and bricks Replace any damaged parts.
Adjust door catch / latch If unable to obtain a tight seal on the door - replace door gasket seal.
Readjust latch after new gasket installed.
Inspect condition and seal of:
Glass Gasket
Door Gasket Perform paper test - replace gasket if required
Paper Test Test the seal on the loading door with a paper bill.
Place a paper bill in the gasketed area of the door on a cold stove–close
the door.
Try to remove the paper by pulling.
The paper should not pull out easily, if it does, try adjusting the door latch,
if that doesn't solve the problem replace the door gasket.
Check and lubricate door hinge + latch Use only high temperature anti seize lube. (ie. never seize)
Check glass for cracks Replace if required.
Clean blower motor Disconnect power supply.
Remove and clean blower.
*DO NOT LUBRICATE*
Inspect and clean chimney Annual professional chimney cleaning recommended.