WOOD Fireplace Insert & Hearth Heater www.regency-fire.com Owners & Installation Manual MODELS: Tested by: 908-332b H2100 I3100L Installer: Please complete the details on the back cover and leave this manual with the homeowner. Homeowner: Please keep these instructions for future reference. FPI FIREPLACE PRODUCTS INTERNATIONAL LTD. 6988 Venture St.
Thank-you for purchasing a REGENCY FIREPLACE PRODUCT. The pride of workmanship that goes into each of our products will give you years of trouble-free enjoyment. Should you have any questions about your product that are not covered in this manual, please contact the REGENCY DEALER in your area. Keep those REGENCY FIRES burning. SAFETY NOTE: If this Insert is not properly installed, a house fire may result.
TABLE OF CONTENTS REGENCY FIREPLACE INSERTS & HEARTH HEATER SAFETY LABEL OPERATING INSTRUCTIONS Safety Label For I3100L ................................................4 Safety Label For H2100M..............................................5 First Fire ......................................................................13 Fan Operation (All Units) .............................................13 Ash Disposal................................................................13 Some Safety Guidelines .......
REPORT NO. 632-323500 106 (MAR.1994) DO NOT REMOVE THIS LABEL A) B) C) D) 13"(330mm) 19"(480 mm) 18"(455 mm) 6.5"(165mm) 908-343b DATE OF MANUFACTURE 2008 2009 2010 JAN FEB MAR APR MAY JUN JUL AUG SEPT OCT NOV MADE IN CANADA DEC FPI FIREPLACE PRODUCTS INTERNATIONAL LTD. 6988 Venture Street Delta, BC V4G 1H4 Manufactured by: INSTALL ONLY ON A NON-COMBUSTIBLE HEARTH RAISED (F) 1.5" (38mm) ABOVE AN ADJACENT COMBUSTIBLE FLOOR.
(Duplicate Serial #) Regency Wood Insert & Hearth Heater 103 DO NOT REMOVE THIS LABEL 103 A) B) C) D) E) F) G) 10 in / 25 in / 14 in / 8.5 in/ 18 in / 1.5 in/ 6 in / 255 mm 635 mm 355 mm 216mm 455 mm 38 mm 150 mm INSTALL ONLY ON A NON-COMBUSTIBLE HEARTH RAISED (F) 1.5 IN / 38 MM ABOVE AN ADJACENT COMBUSTIBLE FLOOR. COMBUSTIBLE FLOOR MUST BE PROTECTED BY NON-COMBUSTIBLE MATERIAL EXTENDING (E) 18 IN / 455 MM TO FRONT AND (G) 6 IN / 150 MM TO SIDES.
INSTALLATION Regency Inserts are constructed with the highest quality materials and assembled under strict quality control procedures that insure years of trouble free and reliable performance. It is important that you read this manual thoroughly and fully understand the safe installation and operating procedures. The more you understand the way your Regency Insert operates, the more enjoyment you will experience from knowing that your unit is operating at peak performance.
INSTALLATION OPTIONAL FLUE CONNECTOR KIT Position the grill on the inside bodyface side and fasten using the bolts, washers and nuts provided (2 per side) as shown in the diagrams. The optional Flue Connector Kit (Part # 846-527) and the Straight Flue Adaptor (Part #846-504) shown here, may be used to produce a secure connection between your flue connector and the insert collar. Detailed installation instructions are included with the kit.
INSTALLATION LEG OPTION ON H2100 HEARTH HEATER INSTALLATION INTO A MASONRY FIREPLACE The addition of legs to the Hearth Heater does not alter its certification, it does not become a freestanding woodstove. The H2100 can only be installed as a Hearth Heater i.e. vented into a masonry or factory built fireplace. When referencing installation or connection to masonry fireplaces or chimneys, the masonry construction must or shall be code complying.
INSTALLATION 4) If the floor of your fireplace is below the level of the fireplace opening, adjust the insert's levelling bolts to accommodate the difference. When additional shimming is required, use non-combustible masonry or steel shims. 5) Measure approximately the alignment of the flue liner with the position of the smoke outlet hole on the insert to check for possible offset. If an offset is required, use a proper stainless steel unit available with the chimney liner.
INSTALLATION FAN / BLOWER Your fan should only be installed once the unit is in place in order to prevent any damage to the fan. To attach, follow the instructions provided with the fan. Make sure to install the rubber grommet to the fan housing before it is installed on the insert. 1) Remove the protective covering from the brass trim on the fan. 2) Align the fan support with the offset clip on the bottom of the ashlip. o erm Th CAUTION: Label all wires prior to disconnection when servicing controls.
INSTALLATION FLOOR PROTECTION Please check to ensure that your floor protection and hearth will meet the standards for clearance to combustibles. Your hearth extension must be made from a non-combustible material. FIREBRICK ASSEMBLY Firebrick is included to extend the life of your insert and radiate heat more evenly. Check to see that all firebricks are in their correct positions and have not become misaligned during shipping.
INSTALLATION Hearth Heater (H2100M) Steel Baffle Place the insulation batt on top of the baffle. Make sure that this batt is laying flat and does not obstruct the smoke from getting up the flue opening. This insulating batt may be wrapped in paper for handling purposes and does not require removal. Batt hold down weights are supplied with the unit and are to be placed on the insulation to either side of the flame spreader as shown in the diagram and at the rear, directly in front of the flue opening.
OPERATING INSTRUCTIONS FIRST FIRE When your installation is completed and inspected, you are ready for your first fire. 1) Open draft control fully. 2) Open firebox door and build a small fire using paper and dry kindling, wait a few minutes for a good updraft in the flue to establish the fire. Leaving the door slightly open will help your fire start more rapidly. CAUTION: Never leave unit unattended if door is left open.
MAINTENANCE 6) Do not permit creosote or soot buildup in the chimney system. Check and clean chimney at regular intervals. 7) Your Regency Insert can be very hot. You may be seriously burned if you touch the insert while it is operating. Warn children of the burn hazard. 8) The insert consumes air while operating, provide adequate ventilation with an air duct or open a window while the insert is in use. 9) Do not use grates, irons or other methods for supporting fuel. Burn directly on the bricks.
PARTS LIST I3100 MAIN ASSEMBLY Part # Description 3) 4) 5) 6) 7) 9) 16) 17) 19) 23) 846-910 846-916 846-304 936-243 846-920 * 948-172/P 846-973 846-570 846-918 948-101 820-235 Door Assembly-Large Gold (I3100)-no glass Door Assembly-Large Black (I3100)-no glass Glass - Replacement - (I3100) 7/8" Adhesive Tape Gasket Glass Retainer Clips (set of 8) Screw 1/4-20 x 3/8" Glass Retainer - Large (I3100) Door Handle Assembly Med.
PARTS LIST I3100 FACEPLATES Part # Description Faceplate: I3100L 163-910 Faceplate & Trim Set - Regular 385) 163-165 Trim Right Regular 386) 163-160 Trim Top Regular 387) 163-161 Trim Left Regular 388) * Faceplate Side Regular 389) * Faceplate Top Regular 163-912 395) 163-164 396) 163-162 397) 163-163 398) * 399) * Faceplate & Trim Set - Oversize Trim Right Oversize Trim Top Oversize Trim Left Oversize Faceplate Side Oversize Faceplate Top Oversize *Not available as a replacement part.
PARTS LIST H2100 MAIN ASSEMBLY 3) 4) 5) 6) 7) 9) 16) 17) 19) 20) Part # 846-910 846-916 846-304 936-243 846-920 * 948-172/P 846-973 846-570 846-918 948-101 948-102 Description Door Assembly-Large Gold - no glass Door Assembly-Large Black - no glass Glass - Replacement 7/8" Adhesive Tape Gasket Glass Retainer Clips (set of 8) Screw 1/4-20 x 3/8" Glass Retainer - Large Door Handle Assembly Med.
PARTS LIST I3100 & H2100 FIREBRICK 70) 71) 72) 75) 76) 78) 81) 84) 85) 18 Part # Description 902-111 802-104 802-146 802-139 802-152 802-143 802-135 802-107 802-156 Brick Regular Full Size: 1-1/4" x 4-1/2" x 9" Brick Partial: 1-1/4" x 4" x 9" Brick Partial: 1-1/4" x 1-3/4" x 9" Brick Partial: 1-1/4" x 4" x 8-3/4" Brick Partial: 1-1/4" x 2" x 9" Brick Partial: 1-1/4" x 2-1/4" x 2-1/4" Brick Partial: 1-1/4" x 1-1/4" x 9" Brick Partial: 1-1/4" x 4-1/2" x 8" Brick Partial: 1-1/4" x 4-1/4" x 8" Regency Woo
WARRANTY Regency Fireplace Products are designed with reliability and simplicity in mind. In addition, our internal Quality Assurance Team carefully inspects each unit thoroughly before it leaves our door. FPI Fireplace Products International Ltd. is pleased to extend this limited lifetime warranty to the original purchaser of a Regency Product. This warranty is not transferable.
Regency fireplace products are designed with reliability and simplicity in mind. In addition, our internal Quality Assurance Team carefully inspects each unit thoroughly before it leaves our door. Fireplace Products International Ltd. is pleased to extend this Limited Lifetime Warranty to the original purchaser of a Regency Product. See the inside back cover for details. Register your Regency online at http://www.regency-fire.