Use and Care & Installation Guide

14 • Residen al Electric Water Heater Use and Care Guide
INSTALLATION
Make electrical
connec ons
WARNING! Working on an ener-
gized circuit can result in severe injury
or death from electrical shock.
NOTICE: Although this water heater is
equipped with Dry-Fire protec on, be
sure the tank is completely lled with
water and all the air is purged from
the tank, before making any electrical
connec ons.
1
Be sure the electrical power
to the water heater is turned
OFF at the circuit breaker
panel (or remove the circuits fuses).
2
Using a non-contact circuit
tester, check the wiring to
make certain the power is OFF.
3
Check the water heaters
data plate and ensure that
the home’s voltage, wiring
size (ampacity) and circuit breaker
ra ng and type are correct for this
water heater. Refer to the wiring
diagram located on the water heater
for the correct electrical connec ons.
Ensure that wire sizes, type, and
connec ons comply with all appli-
cable local codes. In the absence of
local codes, follow NFPA-70 and the
current edi on of the Na onal Electric
Code (NEC).
4
Remove the cover on the
electrical junc on box on the
top of the water heater.
5
Install wiring in an approved
conduit (if required by local
codes). Use a UL listed or CSA
approved strain relief to secure the
electrical wiring to the water heater.
6
Connect the ground wire to
the green ground screw.
Connect the home’s two
power wires to the water heaters
four power wires (black to black, red
to red). Use suitable wire nuts or
other approved means to make the
power connec ons.
NOTICE: The tank must be com-
pletely empty of air and full of
water before connec ng electrical
power to avoid “Dry Firing.” Dry
Firing may result in the upper ele-
ment burning out. This is a com-
mon installa on mistake. A er
you make the water connec ons,
but before you connect the electri-
cal power, open a hot water faucet
and let the water run full un l all
the air is removed. Let the “hot
water run full for three minutes
or longer before connec ng any
electrical wires. A Dry Fired upper
hea ng element is an installa on
error and is not covered under
warranty.
This model is equipped with Dry-
Fire protec on, which will ac vate
an error code if the above steps
are not fully followed.
Step 9:
The water heaters electrical requirements can
be determined from the data plate.
Red Wires
(3)
Ground
Wires
Smart Port
Cover
1/2” Conduit
Connection
Black Wires
(3)
Connec ng the electrical wires.
INSTALLATION