Adapting to another gas
Valid for switching from natural gas H/E to propane and vice versa.
1 Changing the burner nozzles
- Remove the nozzles with a 12 mm spanner and fit the new nozzles
with their new seals.
First tighten the nozzles by hand and carefully lock them using
a spanner. Carry out a leak tightness check.
2 Changing the ignition burner injector
Unscrew the connecting nut (14 spanner),
Pull the gas supply pipe towards yourself.
Take out the ignition burner nozzle.
Fit the new nozzle .
Re-attach the supply tube (14 spanner).
Natural gas H Propane
Nozzle marking 40 30
Nozzle diameter 0.40 mm 0.30 mm