Specifications
31
ZXT-300EU Information
Change Z-Wave-to-IR Channel (EP) on ZXT-300EU
Step Setup Key
LED Indication Status
on ZXT-300EU
1
Press and hold PROG button on
the ZXT-300EU for 3seconds to
start switching the EP
(1->2->3->4->5->6->1->2..)
• LED flashes once=
EP1
• LED flashes twice=
EP2
• LED flashes 3 times=
EP3
• LED flashes 4 times=
EP4
• LED flashes 5 times=
EP5
• LED flashes 6 times=
EP6
How to get the NIF “Node Information Frame" on ZXT-300EU
Step Setup Key
LED Indication Status
on ZXT-300EU
1
Make sure ZXT-300EU switched
to Channel 1 (EP1)
• LED flashes once
then keep on
2
Press the PROG button on the
ZXT-300EU
(EP1 will response “NIF"
EP2, EP3, EP4, EP5, EP6 will
response “Multi-channel
capability report")
• LED flashes once
then keep on
(ZXT-300EU will report
the supported command
class)
L Information
− Please follow this Operating Instructions if you are using Z-
URC
TM
550EU to operate ZXT-300EU.
− If you are using Gateway or other z-wave controllers to
operate ZXT-300EU, Please follow the instruction from the
gateway or other controller.