Specifications

38
which you want to
transmit the IR
signal
on for each
key press
6
Press
Front OK
LED flashes
once and stays
on
-
7
Press the PROG
button on ZXT-
300EU
(The IR port
number has been
assigned to the EP1
as it is ACK by
EP1)
Front OK
LED flashing
then turns off
Set IR Port
output
successful
LED flashes 2
times then
keep on
Set IR Port
output
successful
Note 1: Error LED in front or back on Z-URC
TM
550EU or ZXT-
300EU Red LED flashes 6 times means that the setup process is failed.
Please redo the process again.
Note 2: All the Simple AV Channel / Z-Wave-to-IR Channel will map to
“IR Port 1” in default if user has not go through the above setup
procedure or Z-Wave remote controller does not support “Multi-
channel Command Class”.
IR Output Power
Set IR Output Power Level for each IR port (except IR Port 1)
Step Setup Key
LED Indication
Status on
Z-URC
TM
550EU
LED Indication
Status on
ZXT-300EU
1
Switch ZXT-
300EU to your
target EP no.
such as EP1
-
LED flashes
once then keep
on
2
Press in
Advance Setup
Back OK
LED and front
OK LED
turns on
-
3
Enter the
function code
"2", "8" in the
front
Front OK
LED flashes
once and stays
on for each key
press
-