To connect, insert the regulator inlet into the tank valve and turn the black coupler
clockwise until the coupler tightens up. DO NOT OVER TIGHTEN THE COUPLER.
After completion of assembly, make sure all appliance control valves are OFF then turn the
tank supply valve on and then turn the control valves on the grill to the ‘HI/IGN’ position
for 10 seconds to purge the line of air.
Inspect the hose before each use of the appliance. If it is evident there is abrasion or wear,
or the hose is cut, it must be replaced prior to the appliance being put into operation. The
replacement hose assembly shall be that specified by the manufacturer.
To disconnect, turn the tank valve off. Hold the coupler sleeve and turn counter clockwise.
The inlet line will be disengaged.
If the appliance is not in use, the gas must be turned off at the supply cylinder. Cylinder
must be stored outdoors out of reach of children and must not be stored in a building,
garage or any other enclosed area.
A dented, rusty, outdated or damaged propane cylinder must be replaced immediately.
Check for leaks with a soapy water solution every time the cylinder is
replaced or reconnected. All leaks must be corrected immediately.
Never use an open flame to check for leaks.
LP Tank Requirements:
The L.P. gas cylinder must be constructed and marked in accordance with the
specifications for L.P. gas cylinders of the U.S. Department of Transportation (DOT) and
designed for use with a QCC-1 quick disconnect system only.
The cylinder must be provided with a shut-off valve terminating in an L.P. gas supply
cylinder valve outlet specified, as applicable, for connection Number QCC-1.
The cylinder must be provided with a listed overfilling prevention device. The pressure
The RONHK hose kit is shown here.