Owner Manual

18 | Page
Leak Testing
NE
VER USE AN OPEN FLAME TO CHECK FOR LEAKS.
All gas piping and connections must be tested for leaks after installation or service. All
leaks must be corrected immediately. Remember-before exchanging an empty bottle
for a new one, make sure all control valves are in the “off” position.
With the LP regulator connected to tank and grill and the grill knobs turned to OFF. Open
the valve on the tank. Test for leaks by applying liquid soap solution to all joints. Bubbles
forming indicate gas leak. Fix gas leak before continuing use.
Burner Adjustments
Every grill is thoroughly checked for proper lighting and burner flame pattern. Conditions at
the location may necessitate minor adjustment of the burner air intake, if the flames
are not steady/stable as shown in the figure.
The flame should be full length of the burner, blue and stable. The air intake (if applicable)
should be adjusted ONLY if the flame is lifting off of the ports or has noticeable
amounts of yellow in the flame.