ICP543759PMT Lithium-ion Polymer Battery Pack Rev.0.0 6/13
10. UL 1642 Safety Criteria for Acceptance
Item State Test method Specification
External Short-circuit
Test
Fully Charged Cell terminals are short-circuited for 6 hours
or longer with a resistance of 50mΩ or less.
Tests are to be conducted at room
temperature and 55.
NO EXPLOSION
or FIRE.
Forced-Discharge
Test
Fully Charged Cell is discharged at a current of 1C rate for
2.5 hours. (If current stops by safety or
passive circuit on the battery, test is
finished.)
NO EXPLOSION
or FIRE.
Heating Test Fully Charged The temperature of the oven is to be raised at
a rate of 5±2/min. to a temperature of
130±2, and remains for 10 minutes at this
temperature.
NO EXPLOSION
or FIRE.
Crush Test Fully Charged Crush between two flat plates. Applied
force is about 13kN.
NO EXPLOSION
or FIRE.
Impact Test Fully Charged Impact between bar (15.8mm diameter) and
9 Kg falling material (at a height of 60 cm).
Bar is laid across the center of the test
sample.
NO EXPLOSION
or FIRE.
Drop Test Fully Charged Drop a fully charged cell onto a concrete
floor from the height of 1.8 meters for 6
times per axis.
NO EXPLOSION
or FIRE.
Vibration Test Fully Charged Vibrate the cell in tri-axial directions each
for 90~100 min. in conditions of frequency
10 ~ 55 Hz with amplitude 0.8 mm.
NO EXPLOSION,
or FIRE.
Short Circuit Test Fully Charged The battery shall be subjected to a
short-circuit condition with a wire of
resistance less than 50mΩ for 1 hour.
NO EXPLOSION
or FIRE.
Abnormal Charge
Test
Fully Discharged Charging the battery by 3C and 4.4 V for 7
hrs.
NO EXPLOSION
or FIRE.