Datasheet

Model
Description
Rev.
Page
ICP543759PMT Lithium-ion Polymer Battery Pack Rev.0.0 8/13
12. Charge State of Battery Before Shipment
The battery is charged to approximately 50 % of minimum capacity. Voltage is 3.7V~3.9V.
This measuring test should be performed within one month after shipment from our factory.
13. Handling Precautions
ICP battery pack shall have enough protection for ICP cell from the specification of
electrical, mechanical and environmental characteristics. For use of this battery, must follow as
specified below. Other than UL1642 or above PACK safety requirement conditions listed may
cause major burst, fire, some smoke and it would cause severe performance failure and unsafe for
use. Please be sure to follow instructions carefully.
DANGERS:
(1) Don’t disassemble or modify the battery.
The battery has safety function and protection circuit to avoid the danger. ICP cell is
packaged by Aluminum laminated plastic film which is easy to be damaged by sharp edge
such as pin, needle, edge of devices like nickel tabs, etc. If they have serious damage,
electrolyte leakage, short-circuit between positive and negative tabs, etc., it would cause
the generation, smoke, rupture, or flaming with mishandling.
(2) Don’t incinerate or heat the battery
Don’t use or leave battery nearby fire, stove or heated place (more than 130). These
occur the melting of insulator, damage of safety function, or ignition on electrolyte. In
case that separator made of polymer is melted by high temperature, the internal
short-circuit occurs in individual cells and then it would cause the generating, smoke,
rupture or flaming.
(3) Don’t use any damaged battery
Do not use batteries that are dented or bent on their edge part. ICP batteries are
possible to be damaged by strong mechanical shock and it would cause wire break,
short-circuit inside the cell, leakage of electrolyte, etc.
(4) Don’t use battery nearby the high temperature place or under the blazing sun.
ICP batteries have possibility to be degraded its performance such as capacity, thickness
increase, impendence, etc. The battery will be charged at the abnormal chemical reaction
occurs in the high temperature place. The thickness change may lead to stressing on
battery case/ device, wiring or cell which may have possibility to lead to damage
performance.
(5) Don’t use the unspecified charger.
If the battery is charged with unspecified condition (under high temperature over the
regulated value, excessive high voltage or current over regulated value, or remodeled
charger with PCM failed or disassemble), there are causes that it will be overcharged or
the abnormal chemical reaction will occur in cells. It causes the gas generating, smoke,
rupture or flaming.
E n gineering specification subject to changes without notice.