Specifications

17B-7
PETROL INJECTION
Petrol injection computer: Removal - Refitting
K4M
17B
REMOVAL
I - REMOVAL PREPARATION OPERATION
a Disconnect the battery (see Battery: Removal - Re-
fitting) (80A, Battery).
a Remove the bolt (4) from the channel (5) .
a Move aside the channel.
II - REMOVAL OPERATION
a Disconnect the two injection computer connectors
(9) .
a Remove:
- the injection computer nuts (7) ,
- the injection computer.
Equipment required
Diagnostic tool
Tightening torquesm
injection computer nuts 8 N.m
WARNING
Do not use any product designed to improve the
electrical contact in the injection computer and oxy-
gen sensor connectors or on the bodies of the oxy-
gen sensors.
Failure to respect this advice causes the oxygen
sensor to malfunction and results in failure to com-
ply with the emission control standard.
WARNING
If the connections are corroded, repair the wiring
(see Wiring: Precautions for repair) (Technical
Note 6015A, 88A, Wiring).
145182
145183