Emulation Pod for M30240 Group MCUs User's Manual

( 25 / 58 )
3.3 Selecting Clock Supply
There are two ways to supply a clock to the MCU, using the oscillator circuit of the emulation pod
or using the oscillator circuit on the target system. Table 3.2 lists the factory-settings of each clock
supply.
Table 3.2 Clock supply to the MCU
IMPORTANT
Notes on Changing the Clock Supply:
The clock supply can be set by the Init dialog when starting up the emulator debugger
or inputting CLK command on the script window.
Clock Description Display of emulator debugger Default setting
X
IN-XOUT
Internal oscillator circuit of emulation pod
(OSC-2: 12MHz)
Target system
Internal
External
Yes
-