13: Inhibiting input:
When this input is set to GND(-), it cannot be enabled by the door opener or by entering a code
from user group 1. This input is designed for use with several code locks that control one door
lock. It can be connected to output 14. This is an NPN open collector output.
14: Communication:
This output is normally open and is switched to GND(-) for 5 seconds when the door lock is
opened with a code from user group 1 or a door opener. The output stays connected to GND(-)
when the door is open. It prevents the door from being activated by two keypads at the same
time. It can also prevent different doors from being opened at the same time by the same key-
pad. This allows you to keep different groups of people separate from each other.
15: GND
T5 and 15 form a common GND.
16: Emergency code output:
When the emergency code is entered, output 16 (NON open collector transistor) is switched to
GND(-). The output delivers a maximum current of 100 mA at 24 V/DC. It can be used to trigger
an alarm/siren or automatically notify security personnel.