Instructions

F) Incorrect code input and reporting
Program code Lock
mode
Conrm Remarks
70 1 # 10 consecutive incorrect entries: The
keypad is locked for 30 seconds.
70 2 # 10 consecutive incorrect entries: The
emergency output is activated.
70 5 to 10 # The keypad is locked for 15 minutes after
5–10 incorrect code attempts. You can
unlock the keypad at any time with the
super user code.
70 0 # All security settings are disabled.
G) Door forced open
Program code Function
code
Conrm Remarks
80 0 # Disabled
80 1 # Switched on, enabled for 60 seconds
H) Door release tones
Program code Function
code
Conrm Remarks
81 0 # No warning tone
81 1 # 2 short tones when the door lock is opened
81 2 # 1 long tone when the door lock is opened
17