13. Typical applications
a) Standard wiring for a single code lock
• Connecttheybackdiode(1N4004,includedwiththecodelock)tothedoorlockinseries.
Place the diode as close as possible to the lock. When an inductance is switched off (electro-
magnet in the lock), the energy released is routed through the diode. This prevents damage
to the code lock.
• To prevent an electrostatic charge on the housing and keypad, connect the GND (-) output
to a neutral earthed wire.
• The door LED turns on when the door output is connected. If desired, the LED can be con-
guredtostayswitchedoff.
• Isolate all unused connections to prevent a short circuit.
• Congurethelocktype(“Fail-Safe”or“Fail-Secure”)withprogramcode66.
• The use of a door sensor (input T7) is optional. If no sensor is used, this input must be bridged
toGND.Whenasensorisconnected,thedoorlockcanbeconguredtodothefollowing:
- Automatically disable the lock when the door is closed.
- Trigger an alarm when the door is forced open.
- Sound a warning alarm when the door stays open for a preset duration.